Submitted by Caio Augusto Garcia Ribeiro (cabecapequena@gmail.com) on 2018-08-02T00:52:57Z
No. of bitstreams: 1
RibeiroCaio-FEB-2018.pdf: 5387665 bytes, checksum: 45fcc05a73039b3f0dc0abc7ea10d407 (MD5) / Rejected by Minervina Teixeira Lopes null (vina_lopes@bauru.unesp.br), reason: Solicitamos que realize uma nova submissão seguindo as orientações abaixo:
- corrigir data de defesa;
- inserir Ata de Defesa em substituição a Ata de Qualificação.
Agradecemos a compreensão. on 2018-08-02T16:56:48Z (GMT) / Submitted by Caio Augusto Garcia Ribeiro (cabecapequena@gmail.com) on 2018-08-02T18:17:42Z
No. of bitstreams: 1
RibeiroCaio-FEB-2018.pdf: 5361717 bytes, checksum: 4fc2f5302908b269a3ebe3ecc8d0821f (MD5) / Approved for entry into archive by Minervina Teixeira Lopes null (vina_lopes@bauru.unesp.br) on 2018-08-02T18:43:53Z (GMT) No. of bitstreams: 1
ribeiro_cag_me_bauru.pdf: 5338756 bytes, checksum: 867db632d4c47abc4ed6f4626038d817 (MD5) / Made available in DSpace on 2018-08-02T18:43:53Z (GMT). No. of bitstreams: 1
ribeiro_cag_me_bauru.pdf: 5338756 bytes, checksum: 867db632d4c47abc4ed6f4626038d817 (MD5)
Previous issue date: 2018-06-11 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O ar-condicionado tem-se tornado um dos grandes responsáveis pelo aumento da demanda de energia elétrica no Brasil e no mundo, pois com o desenvolvimento econômico combinado a redução de preço dos equipamentos de ar-condicionados, mais residências e comércios os utilizam em busca de conforto térmico. Mas o uso pode acarretar em um aumento considerável na conta de energia, já que o ar-condicionado é o aparelho doméstico com alto consumo de energia. A solução imediata apontada por Sivak (2009) e Shan et al. (2013) para que o crescimento do uso de arcondicionado não provoque uma crise energética no mundo seria desenvolver aparelhos com a mesma qualidade de refrigeração dos atuais, mas que consumiriam bem menos energia. O aparelho mais utilizado em residências, pequenos comércios e escritórios, é o split system, com o evaporador do tipo Hi-wall, equipamento que tem algumas limitações em relação a sua distribuição de ar, que provoca bolsões de ar quente e frio no mesmo ambiente, além de provocar desconfortos localizados. O controle desse evaporador é baseado na temperatura de retorno, ou seja, se a temperatura no retorno não atingir a temperatura estabelecida o mesmo opera em sua potência máxima por um tempo maior que o necessário, desperdiçando assim energia elétrica, ou a temperatura pode ser alcançada antes no retorno do que no ambiente, provocando assim desconforto térmico por mais tempo. Assim, será proposta neste trabalho uma solução numérica, utilizando um código CFD, a partir das equações diferencias de energia combinada com as equações de Navier–Stokes, em um modelo turbulento semi empírico k-epsilon de duas equações, considerando as três dimensões. Partindo de um caso padrão foram outros 11 casos alterando a altura do evaporador e o ângulo de insuflamento. Com os resultados pôde-se avaliar qual dos 11 casos foi mais eficiente do ponto de vista energético o qual produz melhor conforto térmico, para assim avaliar melhorias que podem ser aplicadas no evaporador hi-wall. / Air conditioning has become one of the main factors responsible for the increase in the electric demand in Brazil and in the world, since with economic development combined with the price reduction of air conditioning equipment, more residences and businesses use them to reach thermal comfort. But the use can lead to a considerable increase in the energy bill, since air conditioning is the household appliance with a high energy consumption. The immediate solution pointed out by Sivak (2009) and Shah et al. (2013), so that the growth of the use of air conditioning does not cause an energy crisis in the world, would be to develop devices with the same quality of refrigeration of the present, but that would consume much less energy. The most commonly devices used in residence, small shops and offices, are Split System, whit a high wall as internal unit, this evaporator has some limitations in the air distribution, which causes hot and cold zones in the same environment, as well as causing localized discomfort. The evaporator control is based on the return temperature, so if the return temperature does not reach the set temperature, the Air Conditioner will operate at its maximum power for a time longer than necessary, thus wasting electrical energy or the set temperature can be reached before in the evaporator than in the environment, thus causing thermal discomfort for longer. Thus, a numerical solution, using a CFD code, will be proposed using the energy-difference equations combined with the Navier-Stokes equations, considering a turbulent flow based in a semi-empirical k-epsilon turbulent model of two equations, considering the three dimensions. And using a model as standard, another 11 models were simulated by changing the height of the evaporator and the angle of inflation. With the results, it can be evaluated which of the 12 cases is more energy efficient and which causes better thermal comfort. And than identify improvements that can be applied in hi-wall units.
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/154783 |
Date | 11 June 2018 |
Creators | Ribeiro, Caio Augusto Garcia |
Contributors | Universidade Estadual Paulista (UNESP), Scalon, Vicente Luiz [UNESP] |
Publisher | Universidade Estadual Paulista (UNESP) |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP |
Rights | info:eu-repo/semantics/openAccess |
Relation | 600, 600 |
Page generated in 0.0032 seconds