A method for high performance output voltage control of a four-leg inverter based three-phase transformerless UPS is proposed. Voltage control loop is employed and the method employs stationary frame resonant filter controllers for the fundamental and harmonic frequency components. A capacitor current feedback loop provides active damping and enhances the output voltage dynamic performance. The
controller design and implementation details are given. Linear and nonlinear loads for balanced and unbalanced load operating conditions are considered. The steadystate
and dynamic performance of the UPS are investigated in detail. A scalar PWM method with implementation simplicity and high performance is proposed and implemented. The control and PWM methods are proven by means of theory,
simulations, and experiments.
Identifer | oai:union.ndltd.org:METU/oai:etd.lib.metu.edu.tr:http://etd.lib.metu.edu.tr/upload/12608151/index.pdf |
Date | 01 January 2007 |
Creators | Demirkutlu, Eyyup |
Contributors | Hava, Ahmet Masum |
Publisher | METU |
Source Sets | Middle East Technical Univ. |
Language | English |
Detected Language | English |
Type | M.S. Thesis |
Format | text/pdf |
Rights | To liberate the content for public access |
Page generated in 0.0018 seconds