There are two types of electric crossing : i ) subterranean / submarine line ii ) overhead-line crossing. We always consider the last one as a more economic option. The inconvenience of an overhead-line crossing would be the environmental constraints among which the existing obstacles, the clearance for the navigation and the aesthetics demanded by the public. The overhead-line crossings usually have conductors of long ranges which are outside of the field of application for the current transmission line codes. These are limited to reaches of a length included between 200 m and 800 m, as well as a height of support lower than 60 m. However, for reaches over 800 m and over a height over 60 m, the criteria of conception in the transmission line codes for the calculation of wind loads are not applicable. In this study we concentrate on loads on the supports owed to the limit wind applied to bare conductors and insulators chains The objective of the present study is to examine the effect of the temporal and spatial correlation of the wind load along the conductors on a finite element model. A special attention was brought to the evaluation of the importance of the dynamic load transmitted on by the conductors and the insulators chains for the case of a turbulent wind load. The numerical study on finite element model for the example of a overhead-line crossing was done with the software ADINA. The wind load for the finite element model for the example of a overhead-line crossing was generated by the software WindGen which uses the method of Simiu-Scanlan and the method of spectral representation developed by Shinozuka-Deodatis. Wind loads generated where integrated into the finite element model ADINA for a dynamic analysis of the overhead-line crossing. For the first part, the current methods are used to calculate the efforts in supports due to the wind loads with an engineering approach and a comparaison approach. The current methods are then compared with the efforts obtained from an advanced method, transient dynamic and spectral stochastic, and specifically for the case of a simple overhead-line and an overhead-line crossings. For the second part, the effect of the longitudinal correlation of the wind load on two parallel conductors was examined. Finally, dynamic experiments on an insulators chain were made to determine the variation of the damping and the rigidity of the system for different type of insulators, different speed of application of the load and the inclination of the insulator.
Identifer | oai:union.ndltd.org:usherbrooke.ca/oai:savoirs.usherbrooke.ca:11143/1541 |
Date | January 2009 |
Creators | Ashby, Mathieu |
Contributors | Légeron, Frédéric |
Publisher | Université de Sherbrooke |
Source Sets | Université de Sherbrooke |
Language | French |
Detected Language | English |
Type | Mémoire |
Rights | © Mathieu Ashby |
Page generated in 0.0019 seconds