This diploma thesis deals with assessment of geometric accuracy of machining center MCV 754 QUICK. BlueSYSTEM digital inclinometers from WYLER AG, XL-80 laser interferometer from RENISHAW, Ballbar QC20-W from RENISHAW and LaserTRACER self-guiding laser interferometer from ETALON AG were used to measure accuracy. Error of the X straightness in the direction of the Z axis was assessed. The first part of the paper describes the geometric accuracy of the machine, currently available instruments for measuring geometric accuracy and an explanation of straightness. The second part consists of the design of measurements, experiment, evaluation and comparison of results and recommendations for teaching.