Return to search

Posouzení geometrické přesnosti obráběcího centra pomocí digitálních inklinometrů / Assessment of geometric accuracy of machining center using digital inclinometers

This diploma thesis deals with assessment of geometric accuracy of machining center MCV 754 QUICK. BlueSYSTEM digital inclinometers from WYLER AG, XL-80 laser interferometer from RENISHAW, Ballbar QC20-W from RENISHAW and LaserTRACER self-guiding laser interferometer from ETALON AG were used to measure accuracy. Error of the X straightness in the direction of the Z axis was assessed. The first part of the paper describes the geometric accuracy of the machine, currently available instruments for measuring geometric accuracy and an explanation of straightness. The second part consists of the design of measurements, experiment, evaluation and comparison of results and recommendations for teaching.

Identiferoai:union.ndltd.org:nusl.cz/oai:invenio.nusl.cz:444307
Date January 2021
CreatorsÚnar, Jan
ContributorsMarek, Tomáš, Holub, Michal
PublisherVysoké učení technické v Brně. Fakulta strojního inženýrství
Source SetsCzech ETDs
LanguageCzech
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/masterThesis
Rightsinfo:eu-repo/semantics/restrictedAccess