This research first examined nitrification inhibition caused by different classes of industrially relevant chemicals on activated sludge and found that conventional aerobic nitrification was inhibited by single pulse inputs of every chemical tested, with 1-chloro-2,4-dinitrobenzene (oxidant) having the most severe impact, followed by alkaline pH 11, cadmium (heavy metal), cyanide, octanol (hydrophobic) and 2,4-dinitrophenol (respiratory uncoupler). Of the different chemicals tested, the oxidative and hydrophobic chemicals showed severe nitrification inhibition relative to other treatment processes and therefore deserved further investigation. For oxidative chemicals, we hypothesized that the more severe inhibition was because nitrifying bacteria lack one or more of the microbial stress response mechanisms used to mediate the toxic effect of oxidative chemicals. During these experiments, we showed that a rapid (minutes) antioxidant potassium efflux mechanism does not exist in two nitrifying bacteria, Nitrosomonas europaea and Nitrospira moscoviensis. Furthermore, we showed that another important antioxidant molecule, glutathione, was not oxidized as readily as in a non-nitrifying bacterium. Furthermore, we hypothesized that hydrophobic chemical-induced nitrification inhibition recovered more quickly because of the presence of membrane modification stress response mechanisms. While testing this hypothesis, we showed that N. europaea modified its cell membrane in response to hydrophobic chemicals using a long-term (hours) membrane modification mechanism that required the synthesis of new fatty acids, but it did not contain a short-term (minutes) response mechanism involving a cis/trans isomerase. Therefore, investigating these nitrifier stress responses showed that nitrifiers lack short-term stress responses that may be used to rapidly detect inhibition, indicating that conventional methods of detecting nitrification inhibition, like differential respirometry and nitrate generation rate (NGR), are still the fastest and easiest methods to use. Because several conventional methods exist, we also investigated differences between differential respirometry and a UV method we developed to measure NGR. During these tests, we showed that the UV NGR method provided a more reliable measure of nitrification inhibition than differential respirometry, and that the time to maximum nitrification inhibition depended on the properties of the chemical toxin, which implies that longer exposure times may be needed to accurately predict nitrification inhibition. / Ph. D.
Identifer | oai:union.ndltd.org:VTETD/oai:vtechworks.lib.vt.edu:10919/28151 |
Date | 21 July 2005 |
Creators | Kelly, Richard Thomas, II |
Contributors | Environmental Engineering, Love, Nancy G., Daigger, Glen T., Novak, John T., Vikesland, Peter J., Stevens, Ann M. |
Publisher | Virginia Tech |
Source Sets | Virginia Tech Theses and Dissertation |
Detected Language | English |
Type | Dissertation |
Format | application/pdf |
Rights | In Copyright, http://rightsstatements.org/vocab/InC/1.0/ |
Relation | KellyIIETDnew.pdf |
Page generated in 0.0026 seconds