Return to search

Determinação de surfactantes e água em formulações de sabonetes líquidos e shampoos por infravermelho por transformada de Fourier (FTIR) utilizando a técnica de reflectância total atenuada (ATR) / Determination of surfactants and water in formulations of shampoos and liquid soaps by fourier transformed infrared (FTIR) using the tecnique of attenuated total reflectance (ATR)

Demonstrou-se pela primeira vez que é possível determinar surfactantes e água em formulações de Sabonetes Líquidos (SL) e Shampoos (SH), direta e simultaneamente pela técnica de infravermelho por transformada de Fourier (FTIR) acoplada à uma cela de reflectância total atenuada (ATR). Tradicionalmente, a principal aplicação do infravermelho médio (2,50 - 15,0 µm) é a identificação de compostos orgânicos. O desenvolvimento de novos acessórios, principalmente de ATR, os avanços na área de microinformática e de métodos quimiométricos, vem viabilizando as análises quantitativas rápidas com excelentes resultados mesmo em meio aquoso. A determinação simultânea de surfactantes em formulações por FTIR-ATR é investigada em detalhes nesta tese. Dentre os surfactantes utilizados, o Lauril Éter Sulfato de Sódio (LESS) e a Cocoamidopropil Betaína (CAPB) são comuns em ambas as formulações, sendo a Coco Dietanolamida (CDEA) empregada em shampoo e o Alquilpoliglicosídeo (APG) em sabonete líquido. Espectros de absorbância de amostras padrão e de verificação foram adquiridos na região do infravermelho médio (800-1600 e 1900-3000 cm-I). Para a regressão de mínimos quadrados clássicos (CLSR), selecionou-se 200 números de onda, enquanto que para a regressão de mínimos quadrados inversos (ILSR), apenas 10. Nas regressões de componentes principais (PCR) e de mínimos quadrados parciais (PLSRI e PLSR2), utilizaram-se de 300 à 1100 números de onda. Dois conjuntos de amostras padrão foram preparados, o primeiro, contendo 27 misturas padrão, foi estudado somente pelos métodos CLSR e ILSR, enquanto que o segundo conjunto, contendo 48 amostras padrão, foi avaliado por todos os métodos mencionados acima. A seleção das regiões de quantificação favoreceu números de onda dos componentes minoritários CAPB, APG e CDEA e resultados satisfatórios foram encontrados para 18 amostras de shampoo e sabonete líquido. Interferentes como NaCl e perfume foram incluídos no segundo conjunto e os métodos PCR e PLSR proporcionaram melhores resultados. Os erros relativos (RSEP%) para água (correspondendo a 84-88% do produto) e LESS (6-10%) não excederam 1%; para CAPB (<3%) e CDEA (<2%), o RSEP% situou-se entre de 2-4% e para APG (<3%), não excedeu 5%. Avaliações do processo de normalização, repetibilidade, vulnerabilidade a interferentes (perfumes), redução no número de padrões de calibração foram conduzidos, encontrando-se resultados satisfatórios para todos os casos, com erro relativo inferior à 5,0%. Um dispositivo simples para injeção direta da amostras no acessório de ATR foi construído, permitindo aumentar a freqüência analítica de 20 para 60 análises por hora. / It is demonstrated for the first time that the principal constituents of a shampoo as well as of a liquid soap -three surfactants and water- can be determined directly, simultaneously and quickly in undiluted samples by Attenuated Total Reflection Fourier Transform Infrared (ATR-FTIR) spectroscopy in the middle infrared region, despite the broad absorption bands ofthe solvent. The main application of the middle infrared (2,50 - 15,0 µm) was the identification of organic compounds. The development of new accessories, such as ATR, and the advance of computers and chemometrics, extended the technique to quantitative analysis, with excellent results. The simultaneous determination of surfactants in shampoos and liquid soap formulations by FTIRA TR is investigated in detail in this thesis. Two of the surfactants, sodium lauryl ether sulfate (LESS) and cocoamidopropyl betaine (CAPB) are common to both formulations; alkylpolyglucoside (APG) is the third surfactant of the liquid soap and cocodiethanolamide (CDEA), the corresponding ingredient of the shampoo. Absorbance data of the undiluted verification samples and calibration standards was collected in the middle infrared region of the spectrum (800-1600 and 1900-3000 cm-1). Five methods of multivariate quantification were compared: Classical Least Squares Regression (CLSR), where absorbance data measured at 200 wavenumbers was processed, Inverse Least Squares Regression (ILSR), were data at 10 selected wavenumbers was analyzed, Principal Components Regression (PCR), and Partial Least Squares Regression, which has two different approaches, PLSR1 and PLSR2. Two sets of standard samples were prepared for the method calibration. The first one, consisting of 27 standard mixtures, was evaluated by the CLSR and ILSR methods; a second set, with 48 standards, was evaluated by all the methods mentioned above. Potential interfering, such as NaCI and perfume, were inc\\uded in this second set. By favoring wavenumbers where absorption bands of the minor components (CAPB in both formulations, APG in the liquid soap and CDEA in the shampoo) are more intense, good results were obtained for 18 simulated samples of shampoo and 18 samples of liquid soap. For the second set, PCR and PLSR methods were most favorable; relative errors (RSEP%) for water (major component, 84-88%) and LESS (6-10%) did not exceed 1%; for CAPB (<3%) and CDEA(<2%), RSEP% of 2-4% were observed, and for APG(<3%), 5% was not exceeded. Tests for repeatability, normalization performance evaluation, effect of interferents presented favorable results. A simple device for direct sample injection was designed and evaluated. It permitted an increase ofthe analytical frequency from 20 to 60 samples per hour.

Identiferoai:union.ndltd.org:usp.br/oai:teses.usp.br:tde-29102007-143925
Date10 August 2005
CreatorsCarolei, Luciano
ContributorsGutz, Ivano Gebhardt Rolf
PublisherBiblioteca Digitais de Teses e Dissertações da USP
Source SetsUniversidade de São Paulo
LanguagePortuguese
Detected LanguagePortuguese
TypeTese de Doutorado
Formatapplication/pdf
RightsLiberar o conteúdo para acesso público.

Page generated in 0.0023 seconds