This master thesis is focused on computational modelling of critical external as well as internal pressure acting of the repaired tank. During cleaning of pipelines, the gas mixture entered into this storage tank causing loss of integrity in the connection between the roof and the shell. The first part of the thesis is focused on check calculation of the shell in exceptional conditions. The next part describes the repair of the tank including check of the pillar according to ČSN EN 1993 1 1 and ČSN EN 1993-1-6. The main part of the thesis is focused on determination of the buckling resistances of the tank in original as well as repaired state using ANSYS Mechanical software. The results are comparable with original tank, whose buckling resistance was not decreased due to the repair.
Identifer | oai:union.ndltd.org:nusl.cz/oai:invenio.nusl.cz:378382 |
Date | January 2018 |
Creators | Ševčík, Martin |
Contributors | Vincour, Dušan, Létal, Tomáš |
Publisher | Vysoké učení technické v Brně. Fakulta strojního inženýrství |
Source Sets | Czech ETDs |
Language | Czech |
Detected Language | English |
Type | info:eu-repo/semantics/masterThesis |
Rights | info:eu-repo/semantics/restrictedAccess |