Return to search

Deformačně napěťová analýza proximálního konce tibie s totální endoprotézou / Strain stress analysis of proximal tibia end with replacement

This thesis deals with stress analysis strain proximal end of tibia with total joint replacements. The analysis is done on the basis of deformation characteristics of voltage, through the finite element method (FEM). We have developed two-dimensional models of the proximal end of tibia with tibial components total endoprosthesis (TEP), without loss and bone loss. Geometry model is created based on data obtained from computerized tomography, which were further processed in the program, Rhinoceros 3.0 and SolidWorks 2009th Computational solution was carried out by finite element method in Ansys Workbench 12.0. The model without loss of bone tissue was tested the hypothesis that the deformation is very small and there is no violation of the shank prosthesis. Due to loss of bone tissue is lost support to the tibial pulse in the proximal tibia and by a progressive increase in stress, which can lead to a breach of the shank total joint replacement. The analysis results show that, if the loss of bone tissue, so that the tibial part of the TEP will lose support, there is a crack stem total hip replacement due to stress.

Identiferoai:union.ndltd.org:nusl.cz/oai:invenio.nusl.cz:229083
Date January 2010
CreatorsTekalová, Soňa
ContributorsMrázek, Michal, Florian, Zdeněk
PublisherVysoké učení technické v Brně. Fakulta strojního inženýrství
Source SetsCzech ETDs
LanguageCzech
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/masterThesis
Rightsinfo:eu-repo/semantics/restrictedAccess

Page generated in 0.0106 seconds