Return to search

Características de sistemas de transmissão tetrafásicos submetidos a transitórios lentos e rápidos

Made available in DSpace on 2014-06-11T19:22:32Z (GMT). No. of bitstreams: 0
Previous issue date: 2012-03-29Bitstream added on 2014-06-13T20:49:12Z : No. of bitstreams: 1
brandt_is_me_ilha.pdf: 996540 bytes, checksum: 97a4b2aa127103d8e81ea086dc41e70e (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Entre tantas tecnologias alternativas desenvolvidas ao longo das últimas décadas, procurando aumentar a eficácia das técnicas convencionais ou propondo novas técnicas não convencionais na transmissão da energia elétrica a longas distâncias e lugares de difícil acesso, o estudo proposto apresenta alguns conceitos e características para sistemas de transmissão constituídos por quatro fases genéricas. O sistema de transmissão tetrafásico tem sido tema de diversos estudos e aplicações em alguns países da Europa e Ásia, apresentando algumas vantagens quando comparado ao sistema de transmissão trifásico convencional. Esse sistema pode ser facilmente integrado ao sistema trifásico por meio de transformadores, amplamente abordado por diversas referências bibliográficas. Nesse estudo foi realizado uma análise comparativa das possíveis sobretensões ocorridas nos domínios da frequência e do tempo entre os sistemas de transmissão trifásico e tetrafásico, avaliando as características elétricas e as respostas transitórias eletromagnética e impulsiva, mostrando novas vantagens sobre esta tecnologia, fornecendo uma avaliação completa sobre o tema / Among the many alternative technologies developed over the past decades, seeking to increase the effectiveness of conventional techniques or proposing new non-conventional techniques in the transmission of electricity over long distances and places of difficult access, the proposed study presents some concepts and features to transmission systems that are constituted of four generic phases. The four-phase transmission system has been subject of numerous studies and applications in some countries in Europe and Asia, presenting some advantages compared to the conventional three-phase transmission system. This system can be easily integrated into the three-phase system through transformers, thoroughly approached by several bibliographical references. In this study was made a comparative analysis of the possible overvoltages that occurred in the areas of frequency and time between the transmission systems of three-phase and four-phase, evaluating the electrical characteristics and the transient answers, electromagnetic and impulsive, showing new advantages over this technology, providing a complete evaluation of this issue

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/87111
Date29 March 2012
CreatorsBrandt, Ivan Scherole [UNESP]
ContributorsUniversidade Estadual Paulista (UNESP), Kurokawa, Sérgio [UNESP]
PublisherUniversidade Estadual Paulista (UNESP)
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format108 f. : il.
SourceAleph, reponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP
Rightsinfo:eu-repo/semantics/openAccess
Relation-1, -1

Page generated in 0.002 seconds