Heat transfer measurements were made in a heat exchanger where air flows parallel to an unbaffled tube bundle and where steam is condensing inside the tubes. The tubes were one-inch outside diameter and were arranged in a square lattice with one-inch clearance between adjacent tubes. The Reynolds Number range covered in this investigation was 630 - 8220.
Pseudo-j(h)-factors have been calculated for the air film in the central unit cell and are presented along with the results of Miller et al and Inayatov and Mikeev, who worked with other lattice arrangements. The present data are insufficiently numerous and too unreliable for empirical correlation, but they do show a trend which is consistent with the work of the above investigators.
The temperature measurements showed an apparent dissymmetry inside the shell of the heat exchanger, and suggestions are made for the improvement of these measurements for more dependable results. Further work that can be done, using the present set-up with slight modifications, is also cited. / Applied Science, Faculty of / Chemical and Biological Engineering, Department of / Graduate
Identifer | oai:union.ndltd.org:UBC/oai:circle.library.ubc.ca:2429/40889 |
Date | January 1958 |
Creators | Chandrasekharan, Kuppanna |
Publisher | University of British Columbia |
Source Sets | University of British Columbia |
Language | English |
Detected Language | English |
Type | Text, Thesis/Dissertation |
Rights | For non-commercial purposes only, such as research, private study and education. Additional conditions apply, see Terms of Use https://open.library.ubc.ca/terms_of_use. |
Page generated in 0.014 seconds