Return to search

The effects of turbulence length scale on heat transfer

The second used a pre-heated flat plate in a transient wind tunnel to determine heat transfer rates with freestream turbulence generated by a number of parallel bar grids. Both liquid crystals and thin film gauges were used for heat-flux studies. A correlation has been derived that defines the heat transfer enhancement in terms of turbulence intensity and integral scale, as well as extending the conclusions of previous workers to apply at high intensities and with severe anisotropy.

Identiferoai:union.ndltd.org:bl.uk/oai:ethos.bl.uk:303615
Date January 1992
CreatorsMoss, Roger W.
ContributorsOldfield, Martin Louis G.
PublisherUniversity of Oxford
Source SetsEthos UK
Detected LanguageEnglish
TypeElectronic Thesis or Dissertation
Sourcehttp://ora.ox.ac.uk/objects/uuid:da82e72d-f91b-4fd7-a773-539cba4681e4

Page generated in 0.0019 seconds