Return to search

Reguladores integrados charge-pump multiplicadores de tensão para aplicações de alta corrente / Integrated charge pump voltage multiplier regulator for high current applications

Orientadores: Jacobus Willibrordus Swart, Jader Alves de Lima Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-15T22:10:27Z (GMT). No. of bitstreams: 1
Mansano_AndreLuisRodrigues_M.pdf: 2816553 bytes, checksum: 2746391c004342d1e0c2d8c4c2f507e8 (MD5)
Previous issue date: 2009 / Resumo: Neste trabalho de Mestrado, foi projetado um conversor DC/DC charge-pump (CP) duplicador de tensão para corrente de carga máxima de 20mA, e que necessita de circuitos de controle para o apropriado acionamento das chaves, regulação de tensão e proteção do estágio duplicador de tensão. O sistema de controle projetado é composto por um circuito de regulação linear (CRL), um regulador Skip, um limitador de corrente (LC) e um circuito de bootstrapping (BOOT) que auxilia o acionamento do estágio duplicador. CP corresponde ao estágio de potência do sistema que faz interface direta com a carga, sendo sua tensão de entrada (PVIN) nominal no valor de 1,5V. O trabalho objetiva obter um conversor DC/DC funcional (demonstrado por resultados de Silício) atingindo resultados experimentais com o menor desvio possível comparados aos valores simulados durante o projeto. A tensão simulada de saída (VOUT), a vazio (sem carga), é 3V. Para carga máxima DC (20mA), o valor de VOUT simulado é de 2,4V. O circuito BOOT gera uma tensão na faixa de 4,5V - 5V, para uma carga DC de 1mA. A corrente limitada pelo bloco LC no circuito duplicador é 30mA. O CLR gera uma tensão inversamente proporcional a VOUT, tendo seus limites mínimo e máximo de 1,3V e 5,2V, respectivamente. Todo o sistema foi integrado no processo de fabricação AMS 0.35um HV, exceto os capacitores do estágio duplicador e do circuito de bootstrapping que são externos. Os resultados experimentais mostram desvio (comparados com simulação) de -12,5% em VOUT @ 20mA DC e -0,13% sem carga, -6% à saída de BOOT @ 1mA DC, +23% CLR mínimo, -3,85% em CRL máximo e +10% na corrente limitada. Durante o desenvolvimento deste trabalho, o Circuito de Regulação Linear (CRL) foi publicado no SBCCI 2009 apresentando sua rápida resposta à transientes de carga, o que é sua grande vantagem comparado a circuitos anteriormente propostos / Abstract: In this work, a DC/DC charge-pump voltage-doubler converter, for maximum load current of 20mA, was designed and fabricated. The Charge Pump (CP) needs control circuits for properly switching, voltage regulation and protection of voltage doubler stage. The control system designed comprises a linear regulation circuit (CRL), a Skip mode regulator, current limitation circuit (LC) and a bootstrapping circuit (BOOT), which provides the appropriate voltage to turn on CP power transistors. The voltage doubler is the power stage that interfaces directly to the load and its nominal input voltage PVIN is 1.5V. The objective of this work is to guarantee that the proposed DC/DC converter works properly (proved by Silicon results) and to achieve experimental results with the least deviation possible compared to simulation. The nominal output voltage (VOUT) with no load is 3V. For maximum DC load (20mA), simulated VOUT is 2.4V. BOOT circuit provides voltage within 4.5V - 5V for DC current load of 1mA. The LC limits the drawn current through the voltage-doubler at 30mA. The CRL provides a control voltage inversely proportional to VOUT and its minimum and maximum are 1.3V and 5.2V respectively. The whole system has been integrated in AMS 0.35um HV except the capacitors of CP and BOOT circuits. The experimental results show deviation (comparing to simulation) of -12,5% on VOUT @ 20mA DC and -0,13% @ no load , -6% on BOOT output @ 1mA DC, +23% CLR minimum, -3,85% CRL maximum and +10% on LC circuit. During the development of this work, the CRL circuit has been published in the SBCCI 2009 conference to present its fast-response to stringent load transient which is the biggest CRL advantage compared to previously proposed circuits / Mestrado / Mestre em Engenharia Elétrica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/259226
Date15 August 2018
CreatorsMansano, Andre Luis Rodrigues
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Lima Filho, Jader Alves, Swart, Jacobus Willibrordus, 1950-, Haddad, Sandro Augusto Pavlik, Fruett, Fabiano
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Elétrica e de Computação, Programa de Pós-Graduação em Engenharia Elétrica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format69 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess