Orientador: Gilberto De Nucci / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-26T05:49:13Z (GMT). No. of bitstreams: 1
Moraes_FernandaCustodio_M.pdf: 2535372 bytes, checksum: 8c0543a6d03f7d2069375240a51187f3 (MD5)
Previous issue date: 2014 / Resumo: Um método simples, seletivo e sensível de cromatografia líquida de alta eficiência acoplada à espectrometria de massa em tandem (CLAE-EM/EM) foi desenvolvido para a determinação de dapaconazol (BL-125) em plasma humano usando tioconazol como padrão interno. As drogas foram extraídas a partir do plasma por uma extração líquido-líquido com éter/hexano (80/20, v/v). A cromatografia foi realizada em uma coluna analítica Genesis C18 partícula 4 ?m (100x2.1mm i.d) com uma fase móvel de metanol/acetonitrila/água (80/10/10,v/v/v) e acetato de amônia (0.5 mM). O dapaconazol foi quantificado usando um espectrômetro de massa com uma fonte de electrospray no modo positivo (ES+) configurado para o modo de monitoramento de múltiplas reações (MRM) para monitorar as transições 415.1 > 159.2 e 387.0 > 131.0 para o dapaconazol e tioconazol, respectivamente. O método teve tempo total de corrida de 3.8 min e uma curva de calibração linear no intervalo de 0.2-100 ng/mL (r = 0.9998). O limite inferior de quantificação (LIQ) foi de 0.2 ng/mL. Os valores de precisão e exatidão do ensaio estavam dentro de ± 10%. Os testes de estabilidade não indicaram nenhuma degradação significativa em condições do experimento. Este método foi usado posteriormente para um estudo de fase I de administração tópica de tosilato de dapaconazol em voluntários humanos saudáveis do sexo masculino / Abstract: A simple, selective and sensitive method based on high-performance liquid chromatography coupled to tandem mass spectrometry (HPLC-MS/MS) has been developed for the determination of dapaconazole (BL-125) in human plasma using tioconazole as internal standard. The drugs were extracted from plasma by liquid-liquid extraction with ether/hexane (80/20, v/v). The chromatography separation was performed on a Genesis C18 analytical column 4 ?m (100 x 2.1 mm i.d.) with a mobile phase of methanol/acetonitrile/water (80/10/10, v/v/v) and ammonium acetate (0.5 mM). Dapaconazole was quantified using a mass spectrometer with an electrospray source in the ESI positive mode (ES+) configured for multiple reaction monitoring (MRM) to monitor the transitions 415.1 > 159.2 and 387.0 > 131.0 for dapaconazole and tioconazole, respectively. The method had a chromatography run time of 3.8 min and a linear calibration curve over the range 0.2 ¿ 100 ng/mL (r = 0.9998). The lower limit of quantification (LLOQ) was 0.2 ng/mL. The precision and accuracy values of the assay were within ±10%. The stability tests indicate no significant degradation under conditions of experiment. This method was used for a phase I study of topical administration of dapaconazole tosylate in healthy human male volunteers / Mestrado / Farmacologia / Mestra em Farmacologia
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/312667 |
Date | 08 April 2014 |
Creators | Moraes, Fernanda Custódio, 1989- |
Contributors | UNIVERSIDADE ESTADUAL DE CAMPINAS, De Nucci, Gilberto, 1958-, Marcondes, Sisi, Muscara, Marcelo Nicolas |
Publisher | [s.n.], Universidade Estadual de Campinas. Faculdade de Ciências Médicas, Programa de Pós-Graduação em Farmacologia |
Source Sets | IBICT Brazilian ETDs |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | 144 p. : il., application/pdf |
Source | reponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0026 seconds