The ever-growing demand for cyber-physical infrastructures has significantly affected worldwide energy consumption and environmental sustainability over the past two decades. Although the average heat load of the computing infrastructures has increased, the supportive capacity of cooling infrastructures requires further improvement. Consequently, energy-efficient cooling architectures, real-time load management, and waste heat utilization strategies have gained attention in the data center (DC) industry. In this dissertation, essential aspects of cooling system modularization, workload management, and waste-heat utilization were addressed. At first, benefits of several legacy and modular DCs were assessed from the viewpoint of the first and second laws of thermodynamics. A computational fluid dynamics simulation-informed thermodynamic energy-exergy formulation captured equipment-level inefficiencies for various cooling architectures and scenarios. Furthermore, underlying reasons and possible strategies to reduce dominant exergy loss components were suggested. Subsequently, strategies to manage cooling parameters and IT workload were developed for the DCs with rack-based and row-based cooling systems. The goal of these management schemes was to fulfill either single or multiple objectives such as energy, exergy, and computing efficiencies. Thermal models coupled to optimization problems revealed the non-trivial tradeoffs across various objective functions and operation parameters. Furthermore, the scalability of the proposed approach for a larger DC was demonstrated. Finally, a waste heat management strategy was developed for new-age infrastructures containing both air- and liquid-cooled servers, one of the critical issues in the DC industry. Exhaust hot water from liquid-cooled servers was used to drive an adsorption chiller, which in turn produced chilled water required for the air-handler units of the air-cooled system. This strategy significantly reduced the energy consumption of existing compression chillers. Furthermore, economic and environmental assessments were performed to discuss the feasibility of this solution for the DC community. The work also investigated the potential tradeoffs between waste heat recovery and computing efficiencies. / Thesis / Doctor of Philosophy (PhD)
Identifer | oai:union.ndltd.org:mcmaster.ca/oai:macsphere.mcmaster.ca:11375/26802 |
Date | January 2021 |
Creators | Gupta, Rohit |
Contributors | Puri, Ishwar K., Mechanical Engineering |
Source Sets | McMaster University |
Language | English |
Detected Language | English |
Type | Thesis |
Page generated in 0.0023 seconds