Parametric study of a wastewater heat recovery system for buildings

Global efforts makes buildings successively more energy efficient. This results in that the percentage of the total energy in the building that is lost to the sewage system, in the form of hot water, is increasing. The characteristics of the wastewater originating from the urban water cycle makes it an attractive heat source which is relatively unexploited. Wastewater heat recovery (WWHR) systems is a group of systems designed to reduce a buildings use of external energy sources by recovering the heat out of the wastewater before it is let out into the sewage.         The focus of this report is a parametric study performed on a WWHR system that utilises thermal storage tanks for accumulation of wastewater and a heat pump equipped with heat exchangers for the heat recovery. The studied variables are the amount of energy that the system is able to recover out of the wastewater and the seasonal average COP of the heat pump. The change of these two variables were analysed both as an affect of parameters dependent of system design and on consumption patterns of the residents of the building. The results showed that by properly designing the system the recovery degree can be increased by 31.5 percentage points reaching values above 90 % and the seasonal average COP can be increased by 13.5 % reaching values of 5.13. However, these two variables stands in contrast to each other were maximising one will reduce the other and it is proposed that it is important to take both into account when evaluating a WWHR system. It is also shown that the consumption related parameters have a relatively big effect on the system. The change in recovery degree as a result of these non-controllable parameter is 14 percentage points and the seasonal average COP changes with 4.2 %.         The system performance as a result of changing the U-value of the heat exchanger connecting the system to the domestic hot water circuit was also analysed. This showed an exponential relation between the U-value and delivered energy from the heat pump. The results showed that an increase of the U-value from 50 W/K to 6000 W/K increased the yearly energy supplied with 37.6 % but an increase from 1000 W/K to 6000 W/K increased the yearly supplied energy with less than 1 %. This result highlights the importance of properly dimensioning the heat exchanger.

Identiferoai:union.ndltd.org:UPSALLA1/oai:DiVA.org:umu-160471
Date January 2019
CreatorsJohansson, Erik
PublisherUmeå universitet, Institutionen för tillämpad fysik och elektronik
Source SetsDiVA Archive at Upsalla University
LanguageEnglish
Detected LanguageEnglish
TypeStudent thesis, info:eu-repo/semantics/bachelorThesis, text
Formatapplication/pdf
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0013 seconds