dis_fernando_dultra.pdf: 2853632 bytes, checksum: d49c5048b5752d02d081d6d5c1615a1b (MD5) / PROSAB,FINEP,CNPq, FAPESB,PROSAB, FAPESB,LABDEA, Acquabrasillis,Caraíba Metais, Pedreiras Limoeiro, Construtora NM / Este trabalho teve por objetivo avaliar o desempenho de filtros intermitentes, no póstratamento
de esgotos sanitários. Primeiramente, o efluente tratado proveio de um
sistema composto por um decantador primário, um contactor biológico rotativo - CBR, e
um decantador secundário. Na segunda fase o CBR saiu de operação, ficando o
tratamento preliminar reduzido a decanto-digestão em três câmaras sépticas, com seis
horas de detenção hidráulica. A unidade experimental é composta de doze unidades de
filtros intermitentes sendo oito de areia, três de escória de metalurgia de cobre, e uma
mista. O sistema trata os esgotos da Escola Politécnica da Universidade Federal da
Bahia. Cada filtro tem 0,5 m de altura de leito filtrante, com tamanhos efetivos-TE de 0,4
mm, 0,75 mm, 1,3 mm de areia e 1,2 mm de escória, os coeficientes de uniformidade
variaram de 1,13 a 1,83. As taxas de aplicação hidráulica foram de 0,4 m³/m².dia,
1,1 m³/m².dia e 1,4 m³/m².dia, com freqüência de aplicação de doses de 48 vezes por
dia. Mesmo com taxas de aplicação mais elevadas que aquelas relatadas em outros
trabalhos, obteve-se resultados satisfatórios quanto à remoção de matéria orgânica,
ficando a DBO abaixo de 10 mg/L e SST em torno de 5 mg/L. Com respeito a eficiência
de redução da matéria orgânica, constata-se que para as elevadas taxas de aplicação,
não há diferença significativa entre os diversos TE’s dos leitos filtrantes.Conclui-se que
é possível obter efluentes de boa qualidade, operando filtros intermitentes com
elevadas taxas de aplicação hidráulica, com leitos de tamanhos efetivos acima de 1,0
mm, sem finos, apresentando carreiras superiores a um ano, o que significa uma
diminuta geração de lodo. Os filtros intermitentes, são unidades aeróbias, não geram
odores, não geram aerossóis, têm baixo custo operacional, não requerem mão de obra
especializada, sua manutenção é simples e econômica, e praticamente não geram lodo.
Sua capacidade de abater microrganismos é limitada, principalmente para taxas mais
elevadas, porem o efluente é muito clarificado possibilitando a aplicação de diversos
processos de desinfecção. Podem ser usados amplamente no tratamento de esgotos
de pequenos geradores, de forma descentralizada e possibilitando o reúso. / This work had the objective of evaluating the performance of intermittent sand filters, in
the post-treatment of sanitary sewers. First, the treated effluent was from a system
composed of a primary decanter, a rotating biological contactor - RBC, and a secondary
decanter. In the second phase the RBC left operation, and the preliminary treatment
was reduced to decant-digestion in three septic chambers, with six hours of hydraulic
detention. The experimental unit is composed of twelve units of intermittent filters which
eight of sand, three of slag of copper metallurgy, and one mixing. The system treated
the sanitary sewers of the Polytechnic School of the Federal University of Bahia. Each
filter had 0,5 m of height of filter stream bed, with effective sizes-ES of 0,4 mm, 0,75
mm, 1,3 mm of sand and 1,2 mm of slag, uniformity coefficients ranged of 1,13 up to
1,83. Rates of hydraulic application had been of 0,4 m ³ /m ².day, 1.1 m ³ /m ².day and
1,4 m ³ /m ².day, with application frequency of doses of 48 times per day. Even with
rates of application higher than those reported in other works, it was gotten satisfactory
results respecting to the removal of organic matter, with BOD below 10 mg/L and SST
around 5 mg/L. Concerning to the organic matter efficiency reduction, one evidences
that for the high rates of application, there was no significant difference between diverse
ES of the filter stream beds. One concludes that it is possible to get good quality
effluent, operating intermittent sand filters with high rates of hydraulic application, with
stream beds of effective sizes above 1,0 mm, without fines, presenting careers superior
to one year, meaning a low generation of sludge. The intermittent filters are aerobic
units, do not generate odors, do not generate aerosols, have low operational cost, do
not require skilled worker, its maintenance is easy and economic and they practically do
not generate sludge. Its capacity to reduce microorganisms is limited, mainly for higher
rates; however the effluent is very clear making possible the application of various
disinfection processes. They can be widely used in treatment sewers of small sources,
in decentralized way and making reuse possible.
Identifer | oai:union.ndltd.org:IBICT/oai:192.168.11:11:ri/21686 |
Date | 23 March 2007 |
Creators | Dultra, Fernando de Almeida |
Contributors | Kiperstok, Asher, Oliveira, Iara Brandão de, Kiperstok, Asher, Oliveira, Iara Brandão de, Andrade Neto, Cícero Onofre de |
Publisher | Universidade Federal da Bahia, Departamento de Engenharia Quimica, Engenharia Industrial, PEI, brasil |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UFBA, instname:Universidade Federal da Bahia, instacron:UFBA |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0017 seconds