Submitted by Renata Lopes (renatasil82@gmail.com) on 2017-06-22T17:42:42Z
No. of bitstreams: 1
jussarareginapereirabritto.pdf: 2008279 bytes, checksum: 81f1e8b058921cfb73367f7e41a7ae65 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2017-08-07T19:23:25Z (GMT) No. of bitstreams: 1
jussarareginapereirabritto.pdf: 2008279 bytes, checksum: 81f1e8b058921cfb73367f7e41a7ae65 (MD5) / Made available in DSpace on 2017-08-07T19:23:25Z (GMT). No. of bitstreams: 1
jussarareginapereirabritto.pdf: 2008279 bytes, checksum: 81f1e8b058921cfb73367f7e41a7ae65 (MD5)
Previous issue date: 2014-08-25 / Os amputados traumáticos de membros inferiores apresentam maior morbidade e mortalidade por doenças cardiovasculares quando comparados à população geral. Entretanto, os fatores de risco para esse aumento de morbidade, bem como os mecanismos patofisiológicos responsáveis, ainda não estão bem esclarecidos. O objetivo do presente estudo foi testar as hipóteses que o uso da prótese em amputados transtibiais traumáticos aumenta a pressão arterial (PA) e a frequência cardíaca (FC) e diminui a variabilidade da frequência cardíaca (VFC), na postura supina (PS) e postura ortostática (PO). Foram avaliados 20 indivíduos adultos, do sexo masculino, sendo 10 com amputações transtibiais unilaterais traumáticas e 10 indivíduos sem amputações (controles). O registro da FC, para o cálculo das medidas de VFC, foi realizado por meio do monitor de frequência cardíaca Polar® modelo RS300CX e a PA foi aferida pelo método auscultatório e oscilométrico. Os grupos foram avaliados em repouso, na PS e PO, sendo os amputados submetidos ao protocolo com e sem a prótese. Para comparações intragrupo foi realizada a ANOVA 2x2 de medidas repetidas e testes t pareados; e na comparação entre grupos, utilizou-se o teste t de Student para amostras independentes. O grupo amputados, com e sem a prótese, foi observado que a FC é maior na PO comparada a PS, (82,5 ± 11,1 vs. 66,8 ± 6,7 bpm respectivamente) e que ao utilizarem a prótese a FC foi maior comparada à condição sem prótese, (76,8 ± 9,0 vs. 72,5 ± 8,0 bpm respectivamente). Analisando as variáveis autonômicas dos amputados na PO comparada a PS, eles apresentaram menores valores de iRR (763,0 ± 100,3 vs. 911,0 ± 89,9; p < 0,001), rMSSD (23,0 ± 14,0 vs. 37,7 ± 21,5; p = 0,001), pNN50 (5,9 ± 9,4 vs. 16,8 ± 18,6; p = 0,01) e HF (24,5 ± 15,0 vs. 42,8 ± 18,8; p = 0,02) e maiores valores de LF (77,1 ± 12,7 vs. 57,2 ± 18,8; p = 0,04) e LF/HF (5,9 ± 5,7 vs. 2,1 ± 1,7; p = 0,07). Quanto ao uso de prótese, foram observados menores valores de iRR (814,6 ± 92,2 vs. 859,4 ± 92,2; p = 0,001), rMSSD (26,6 ± 14,8 vs. 34,2 ± 20,1; p = 0,002) e pNN50 (8,9 ± 11,9 vs. 13,7 ± 15,4; p = 0,005) em comparação com a condição sem prótese. Comparando ao grupo controle, a FC dos amputados com o uso da prótese foi maior tanto na PS quanto na PO, ao passo que quando a prótese foi retirada, essa diferença desaparecia. Conclui-se que o uso da prótese altera as variáveis hemodinâmicas por meio do aumento da FC e da PA e das variáveis autonômicas por meio da redução da VFC. / The traumatic lower limb amputees have higher morbidity and mortality from cardiovascular disease compared to the general population. However, the risk factors for this increased morbidity, as well as the pathophysiological mechanisms responsible are not well understood. The aim of this study was to test the hypothesis that the use of the prosthesis in transtibial amputees traumatic increases blood pressure (BP) and heart rate (HR) and decreased heart rate variability (HRV) in the supine posture (PS) and standing position (PO). 20 individuals, males, 10 with unilateral transtibial amputations and traumatic amputations 10 individuals without (controls) were evaluated. The registration of the FC, for the calculation of measures of HRV was performed by means of the heart rate Polar ® RS300CX model and BP monitor was checked by auscultation and oscillometry. The groups were evaluated at rest, the PS and PO, being amputees undergoing the protocol with and without the prosthesis. For intragroup comparisons 2x2 ANOVA repeated measures and paired t tests were performed; and comparison groups was used for independent samples Student's t test. The amputee group, with or without the prosthesis, it was found that FC is larger compared to PO the PS (82.5 ± 11.1 vs. 66.8 ± 6.7 beats per minute respectively) and that when using the prosthesis HR was higher compared to unaided, (76.8 ± 9.0 vs. 72.5 ± 8.0 bpm respectively). Analyzing the autonomic variables of amputees in PO compared to PS, they had lower values of RR intervals (763.0 ± 100.3 vs. 911.0 ± 89.9, p <0.001), rMSSD (23.0 ± 14.0 vs. 37.7 ± 21.5, p = 0.001), pNN50 (5.9 ± 9.4 vs. 16.8 ± 18.6, p = 0.01) and HF (24.5 ± 15.0 vs. 42.8 ± 18.8, p = 0.02) and higher values of LF (77.1 ± 12.7 vs. 57.2 ± 18.8, p = 0.04) and LF / HF (5.9 ± 5.7 vs. 2.1 ± 1.7, p = 0.07). Regarding the use of prosthesis, lower values of RR intervals (814.6 ± 92.2 vs. 859.4 ± 92.2, p = 0.001) were observed, rMSSD (26.6 ± 14.8 vs. 34.2 ± 20.1, p = 0.002) and pNN50 (11.9 ± 8.9 vs. 13.7 ± 15.4, p = 0.005) compared to the unaided. Compared to the control group, HR amputees using prostheses was higher both in PS as in PO, whereas when the prosthesis was removed, this difference disappeared. We conclude that the use of the prosthesis alters hemodynamic variables by increasing HR and BP and autonomic variables by reduced HRV.
Identifer | oai:union.ndltd.org:IBICT/oai:hermes.cpd.ufjf.br:ufjf/5305 |
Date | 25 August 2014 |
Creators | Britto, Jussara Regina Pereira |
Contributors | Lima, Jorge Roberto Perrout de, Laterza, Mateus Camaroti, Werneck, Francisco Zacaron |
Publisher | Universidade Federal de Juiz de Fora (UFJF), Programa de Pós-graduação em Educação Física, UFJF, Brasil, Faculdade de Educação Física |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | English |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Source | reponame:Repositório Institucional da UFJF, instname:Universidade Federal de Juiz de Fora, instacron:UFJF |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0031 seconds