Comparação de métodos multirresíduos para determinação de produtos fitossanitários em polpa e casca de banana / Comparation of multiresidue methods for phytosanitary products determination in banana ́s pulp and peel

Submitted by Reginaldo Soares de Freitas (reginaldo.freitas@ufv.br) on 2016-05-03T15:23:48Z
No. of bitstreams: 1
texto completo.pdf: 1342752 bytes, checksum: 830cdb006358d1a367932bde92e59c1c (MD5) / Made available in DSpace on 2016-05-03T15:23:48Z (GMT). No. of bitstreams: 1
texto completo.pdf: 1342752 bytes, checksum: 830cdb006358d1a367932bde92e59c1c (MD5)
Previous issue date: 2015-03-19 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este estudo buscou otimizar e validar a extração sólido-líquido com partição em baixa temperatura (ESL/PBT), adaptar e validar a extração QuEChERS (do inglês Quick Easy Cheap Effective Rugged Safe Method) e comparar os dois métodos validados para determinação de seis agrotóxicos (azoxistrobina, bifentrina, clorotalonil, clorpirifós, difenoconazol e imazalil) na polpa e na casca de banana da cultura Prata, seguida da análise por cromatografia gasosa com detector por captura de elétrons (CG/DCE). Os resultados obtidos para os parâmetros analíticos avaliados mostraram eficiência adequada na etapa de clean-up, tanto para a ESL/PBT, como para QuEChERS em ambas as matrizes. Em relação ao efeito de matriz observou-se que os componentes da matriz influenciam na quantificação dos agrotóxicos, sendo que cada composto apresentou comportamento distinto. Comparando as curvas analíticas dos extratos utilizando a ESL/PBT e o QuEChERS, não existem diferenças significativas para nenhum dos agrotóxicos estudados. Os métodos apresentaram-se seletivos para as duas matrizes. O coeficiente de correlação para ambos os métodos foram 0,995 nas duas matrizes, indicando boa linearidade. Na polpa, a ESL/PBT apresentou menores valores de limite de detecção (LD entre 2,1-5,7 μg kg-1) e quantificação (LQ entre 6,8-17,3 μg kg-1) comparado com o QuEChERS (LD entre 4,2-14,7 μg kg-1 e LQ entre 12,9-44,6 μg kg-1). Para a casca, o QuEChERS apresentou menores valores de limite de detecção (LD entre 3,1-14,7 μg kg-1) e quantificação (LQ entre 9,5-44,6 μg kg-1) comparado com a ESL/PBT (LD entre 3,0-29,8 μg kg-1 e LQ entre 9,2-90,2 μg kg-1). Tanto a polpa como a casca, em ambos os métodos, apresentaram limites de quantificação abaixo dos limites máximos de resíduos (LMR) estabelecidos pela União Europeia e Codex Alimentarius. Os métodos foram precisos, apresentando coeficientes de variação entre 0,5%-16,4%. Os métodos se mostraram exatos para a maioria dos agrotóxicos, tanto na polpa, como na casca da banana. Foi observado que, de modo geral, as mudanças químicas ocorridas nos diferentes estádios de maturação da banana, não interferiram nas respostas cromatográficas dos agrotóxicos. Além disso, foi observado também que os extratos obtidos em ambos os métodos se mantêm estáveis por mais de cinco semanas, independente da matriz. Os métodos validados podem ser aplicados para determinação desses agrotóxicos na banana inteira (polpa e casca) apresentando porcentagens de recuperação entre 80,1%-140,1%. Os métodos validados foram aplicados em amostras de banana adquiridas no comércio de Viçosa, utilizando tanto a ESL/PBT como o QuEChERS, na polpa como na casca. Não foram encontrados resíduos dos agrotóxicos estudados em nenhuma das amostras. / This study aimed to optimize and validate the solid-liquid extraction with partition at low temperature (SLE/PLT), adapt and validate QuEChERS extraction (Quick Easy Cheap Effective Rugged Safe Method) and compare both of validated methods for determination of six pesticides (azoxystrobin, bifenthrin, chlorothalonil, chlorpyrifos, difenoconazole and imazalil) in banana ́s pulp and peel, followed by gas chromatography with electron capture detector (GC/ECD) analysis. The results for analytical parameters showed adequate efficiency for the clean-up stage for both SLE/PLT, and QuEChERS in both matrixes. In relation to matrix effect has been observed that matrix ́s components influence the quantification of pesticides, each compound showed different behavior. Comparing analytical curves of the extracts using SLE/PLT and QuEChERS, there are no significant differences for any of the pesticides studied. The methods presented were selective for the two matrixes. The correlation coefficients for both methods were for both matrixes were ≤ 0.995, indicating good linearity. In pulp, SLE/PLT showed lower detection limits values (LOD between 2.1 to 5.7 μg kg-1) and quantification limits (LOQ between 6.8 to 17.3 μg kg-1) compared to QuEChERS (LOD between 4.2 to 14.7 μg kg-1 and LQ between 12.9 to 44.6 μg kg-1). For peel, QuEChERS showed lower detection limit values (LOD between 3.1 to 14.7 μg kg-1) and quantification limits (LOQ between 9.5 to 44.6 μg kg-1) compared to SLE/PLT (LOD between 3.0 to 29.8 μg kg-1 and LQ between 9.2 to 90.2 μg kg-1). Both, pulp and peel, with both methods, presented quantification limits below the maximum residue limits (MRLs) established by the European Union and Codex Alimentarius. The methods used were accurate, with coefficients of variation between 0.5% -16.4%. The methods proved accurate for most pesticides, both in banana ́s pulp and peel. It was observed that, in general, the chemical changes occurring in different banana ripening stages, did not interfere with chromatographic responses of pesticides. Furthermore, it was also observed that the extracts obtained with both methods are stable for more than five weeks, regardless of the matrix. Validated methods can be applied to determination of these pesticides in the whole banana (peel and pulp) having recovery percentages between 80.1% -140.1%. The validated methods were applied in banana samples collected in Viçosa, using both SLE/PLT as QuEChERS, for both matrixes. No pesticide residues were found in any of the samples studied.

Identiferoai:union.ndltd.org:IBICT/oai:localhost:123456789/7605
Date19 March 2015
CreatorsEsquivel Hernández, Adriana de Los Angeles
ContributorsNeves, Antônio Augusto, Oliveira, André Fernando de, Queiroz, Maria Eliana Lopes Ribeiro de
PublisherUniversidade Federal de Viçosa
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFV, instname:Universidade Federal de Viçosa, instacron:UFV
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0022 seconds