Return to search

Investigação e análise de parâmetros geotécnicos obtidos com ensaios de laboratório e ensaios in situ (DMT, PMT, SPT, PDM) / Investigation and analysis of geotechnical parameters obtained with laboratory tests and in situ tests (DMT, PMT, SPT, PDM)

Submitted by Reginaldo Soares de Freitas (reginaldo.freitas@ufv.br) on 2017-03-02T19:00:23Z
No. of bitstreams: 1
texto completo.pdf: 1455701 bytes, checksum: cf27fd75f7d19be8eb91169c29a503c3 (MD5) / Made available in DSpace on 2017-03-02T19:00:23Z (GMT). No. of bitstreams: 1
texto completo.pdf: 1455701 bytes, checksum: cf27fd75f7d19be8eb91169c29a503c3 (MD5)
Previous issue date: 2003-04-25 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este trabalho tem como objetivo analisar os parâmetros geotécnicos obtidos a partir de dados provenientes dos campos experimentais de Viçosa - M.G. (solo residual de gnaisse), e de Serra - Grande Vitória - E.S (solo residual proveniente de rocha sedimentar). Além disso, verifica a validade de algumas correlações encontradas na literatura e proposição de novas correlações baseadas nestes parâmetros. Foi feita a comparação entre a classificação unificada e a classificação quanto ao tipo de solo, obtidos pelo ensaio DMT, bem como a verificação da influência da sucção em alguns de seus parâmetros. São abordados os seguintes ensaios: (i) de campo: ensaio pressiométrico de pré-furo - PMT, ensaio dilatométrico - DMT, índice de resistência à penetração - SPT, ensaio de penetração dinâmica – PDM; (ii) de laboratório: ensaio edométrico, ensaio triaxial convencional, determinação da curva característica do solo, ensaios de caracterização (granulometria conjunta, massa específica dos sólidos, teor de umidade da amostra no estado natural, limite de liquidez, limite de xxviii plasticidade). Não foi realizado o ensaio PDM no campo experimental de Viçosa. No campo experimental de Serra, dentre os ensaios de laboratório, foram executados apenas os ensaios de caracterização. Como conseqüência deste estudo, infere-se a importância da consideração da sucção em parâmetros baseados na teoria clássica da mecânica dos solos, com o intuito de que não haja interpretações errôneas dos mesmos. Comparando-se as equações encontradas na literatura e as obtidas neste estudo, nota-se a existência de certa discrepância entre elas. Conclui-se então haver a necessidade da utilização de quaisquer correlações apenas para se prever a ordem de grandeza dos parâmetros envolvidos. / This work has the objective of analyzing the geotechnical parameters calculated from data of the experimental fields of Viçosa - M.G. (gnaisse residual soil), and from the Serra - Great Vitória - E.S (soil originating from residual sedimentary rock). Also it was verified the validity of some correlations found in the literature and proposition of new correlations based on these parameters. It was made the comparison between the unified classification and the classification in relation to the soil type, obtained by the DMT test, as well as the verification of the influence of the suction in some of these parameters. The field tests were: pressuremeter test - PMT, dilatometer test - DMT, Standard Penetration Test - SPT, Dynamic Manual Penetration Test- PDM and laboratory tests: Oedometer, conventional triaxial test, determination of soil characteristic curve, characterization test (united granulometric, specific mass of the solids, percentage of humidity of the sample in the natural state, liquidity limit, plasticity limit). The PDM test was not performed in the experimental field of xxx Viçosa. In the experimental field of the Serra, among the laboratory tests, the only one executed was the characterization tests. As a consequence of this study, it was noticed the importance of the consideration of the suction in parameters based on the classic theory of the mechanics of the soils, with the intention to prevent thaws erroneous interpretation of them. Comparing the equations found in the literature and the ones obtained in this study, it is noticed the existence of certain discrepancy among them. The need of correlations usage is concluded. In this case the in situ testing data should just be used to foresee the greatness order of the geotechnical parameters.

Identiferoai:union.ndltd.org:IBICT/oai:localhost:123456789/9667
Date25 April 2003
CreatorsCustódio, Gisele Santos
ContributorsLima, Dario Cardoso de, Azevedo, Roberto Francisco de, Minette, Enivaldo
PublisherUniversidade Federal de Viçosa
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFV, instname:Universidade Federal de Viçosa, instacron:UFV
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0026 seconds