Dispersão de traçador em medições de vazões em tubulações

Submitted by Fatima Fonseca (fatima.fonseca@sibi.ufrj.br) on 2017-07-28T13:46:40Z
No. of bitstreams: 1
132612.pdf: 2624940 bytes, checksum: 945359c75b502dae428523337d344f23 (MD5) / Made available in DSpace on 2017-07-28T13:46:40Z (GMT). No. of bitstreams: 1
132612.pdf: 2624940 bytes, checksum: 945359c75b502dae428523337d344f23 (MD5)
Previous issue date: 1973-01 / Este trabalho resultou da necessidade de se medir vazões no sistema de refrigeração de uma fábrica de borracha (FABOR) e no sistema de abastecimento de água do complexo petroquímico de Duque de Caxias, Estado do Rio de Janeiro (principalmente, REDUC e FABOR). As medições foram realizadas pelo método Pico-a-Pico, com o auxílio de dois conjuntos de medição completamente independentes. É mostrado que uma precisão melhor que noventa e nove por cento, ou seja, erros inferiores a um por cento, pode ser facilmente obtida por este método, em determinações da velocidade média do escoamento. Em geral, a precisão depende em grande parte da precisão da área da seção transversal da tubulação. É proposto aqui um novo e aperfeiçoado método de interpretação, bem como se apresenta um completo procedimento de medição. Uma análise do coeficiente de dispersão experimental mostrou excelente concordância com o valor teórico, para uma tubulação reta e um considerável acréscimo deste valor para tubulações com curvas, válvulas, derivações, etc. Os valores reais obtidos para o coeficiente de dispersão estão sendo utilizados no planejamento de outros trabalhos semelhantes. A análise das curvas de dispersão medidas (picos) parece indicar que uma melhor descrição teórica é obtida quando se aplica uma nova solução da equação da dispersão. / This work resulted from a need to measure flow rates in the cooling system of a rubber factory (FABOR) and in the water supply system of whole petrochemical complex in Duque de Caixas, State of Rio de Janeiro (mainly REDUC refinery an FABOR factory). Measurements were perfomed by the so-called Peak-to-Peak method with two completely independed measuring systems. It has been shown than an accuracy better than one percent is easily obtainable by this method for the flow velocity measurement. Overall accuracy of the flow rate depends finally on the accuracy of the cross-section area of the pipeline. A new, improved, method of interpretation has been proposed and a complete measurement procedure worked out. Analyse of the dispersion coefficient showed a very good agreement with theoretical value for a smooth pipeline, and a considerable increase of its value for pipelines with bends, valves, etc. Obtained real values of the dispersion coefficient were already used for the planning of other similar works. Analyse of the measured dispersion curves (peaks) seems to indicate that a better theoretical description is obtained when a new solution of the dispersion equation is applied.

Identiferoai:union.ndltd.org:IBICT/oai:pantheon.ufrj.br:11422/2531
Date01 1900
CreatorsRoldão, João Sérgio Fajardo
ContributorsZuber, Andrzej B.
PublisherUniversidade Federal do Rio de Janeiro, Programa de Pós-Graduação em Engenharia Civil, UFRJ, Brasil, Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa em Engenharia
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UFRJ, instname:Universidade Federal do Rio de Janeiro, instacron:UFRJ
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0119 seconds