Previous issue date: 1976-04 / A obtenção de parâmetros hiperbólicos a serem utilizados numa análise de tensões e deformações, pelo método dos elementos finitos, é feita a partir de ensaios triaxiais em amostras de solo indeformadas. O solo estudado foi uma areia contendo 7% de argila e 8% de silte. Extrairam-se duas amostras indeformadas em bloco, com dimensões aproximadas de 30 x 30 x 30 cm, da cava do metrô do Rio de Janeiro ao lado do Palácio Monroe, em pontos situados a 10,50 m e 12,00 m de profundidade, e distantes horizontalmente em cerca de 20 m. Foram ensaiados corpos de prova sob condições não-drenada e adensada-drenada. Os ensaios adensados-drenados foram executados segundo dois caminhos de tensões: 1) σ1 crescente e σ3 constante, 2) σ1 constante e σ3 decrescente. Desenvolveram-se programas de computador para cálculo e desenho dos ensaios não-drenados e para obtenção dos parâmetros hiperbólicos dos ensaios drenados com σ1 crescentes e σ3 constante. Esses programas e outros para obtenção dos parâmetros de resistência ao cisalhamento são listados em apêndices. Os resultados dos ensaios drenados foram utilizados na análise de uma escavação escorada, nos trabalhos de tese de Jorge Fujii e Mitsuo Tsutsumi, da COPPE-UFRJ. / Hyperbolic parameters to be used in stress-strain analysis by the Finite Element Method are obtained with triaxial tests on undisturbed soil samples. The soil studied was a sand containing 7% clay and 8% silt. Two 30 x 30 x 30 cm undisturbed samples were collected in the subway excavation, near Monroe Palace, in Rio de Janeiro. Sample locations were, 10,50 m and 12,00 m deep, and approximately 20 m apart. Tests under consolidated-undrained and consolidated-drained conditions were carried out. The consolidated-drained
tests were performed under two stress-paths: 1) σ1 increasing, σ3 constant, 2) σ1 constant, σ3 decreasing. Computer programs were developed in order to elaborate tests results and to obtain the hyperbolic parameters automatically. These programs as well as others concernig the shear parameters are listed herein. The results of the consolidated-drained tests were used by Jorge Fujii and Mitsuo Tsutsumi, as they performed the analysis of a braced excavation, in their M.Sc. thesis, COPPE//UFRJ.

Identiferoai:union.ndltd.org:IBICT/oai:pantheon.ufrj.br:11422/2775
Date04 1900
CreatorsPeixoto, Francisco José Lins
ContributorsLacerda, Willy Alvarenga
PublisherUniversidade Federal do Rio de Janeiro, Programa de Pós-Graduação em Engenharia Civil, UFRJ, Brasil, Instituto Alberto Luiz Coimbra de Pós-Graduação e Pesquisa em Engenharia