Return to search

Análise do impacto de geradores fotovoltaicos na estabilidade transitória de geradores síncronos distribuídos / Analysis of the impact of photovoltaic generators on the transient stability of distributed synchronous generators

Submitted by Kelren Mota (kelrenlima@ufpa.br) on 2018-06-13T19:53:39Z
No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertação_AnaliseImpactoGeradores.pdf: 1807062 bytes, checksum: 70cccf54fcf4a578677d62ea69daa518 (MD5) / Approved for entry into archive by Kelren Mota (kelrenlima@ufpa.br) on 2018-06-13T20:05:35Z (GMT) No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertação_AnaliseImpactoGeradores.pdf: 1807062 bytes, checksum: 70cccf54fcf4a578677d62ea69daa518 (MD5) / Made available in DSpace on 2018-06-13T20:05:35Z (GMT). No. of bitstreams: 2
license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5)
Dissertação_AnaliseImpactoGeradores.pdf: 1807062 bytes, checksum: 70cccf54fcf4a578677d62ea69daa518 (MD5)
Previous issue date: 2018-02-19 / Esta Dissertação de Mestrado tem por objetivo apresentar uma análise comparativa entre dois modelos de controles de inversores para o estudo da análise da estabilidade transitória e estabilidade de tensão, com a inserção da geração fotovoltaica nas redes elétricas de distribuição. É proposto também uma análise da influência, tanto negativa quanto positiva, causada pelos modos de controle desses inversores na estabilidade da máquina síncrona interconectada ao sistema elétrico. Uma outra solução a ser investigada neste trabalho será o uso do modo de controle de potência reativa dos geradores fotovoltaicos via inversor, que possa contribuir para o alivio da demanda de reativo dos geradores síncronos distribuídos interligados no mesmo sistema elétrico, com o objetivo de reduzir a possibilidade de gerar uma condição de instabilidade de tensão, após uma grande perturbação, ou quando da ocorrência de contingências no sistema elétrico de potência que possam afetar redes elétricas fracas ou sobrecarregadas e com grande inserção de geradores fotovoltaicos. As análises dos modelos de controle serão realizadas por meio de simulações no domínio do tempo, através da ferramenta computacional ANATEM e ANAREDE. / This dissertation aims to present a comparative analysis between two models of inverter control for the study of the transient stability analysis and voltage stability, with the insertion of the photovoltaic generation in the distribution electric grid. It is also proposed an analysis of the influence, both negative and positive, caused by the control modes of these inverters in the stability of synchronous machine connected to the grid. Another proposed solution to be investigated in this work will be the use of the reactive power control mode of photovoltaic generators via the inverter, which can contribute to the relief of the reactive demand of distributed synchronous generators interconnected in the same electric system, in order to reduce the possibility of generating a voltage instability condition, after a big disturbance, or in the occurrence of contingencies in the electric power system that may affect weak or overloaded electrical grids and with large insertion of photovoltaic generators. The analysis of the control models will be carried out through simulations in the time domain, through the ANATEM and ANAREDE computational tools.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.ufpa.br:2011/10016
Date19 February 2018
CreatorsPINHEIRO, Wanessa Tâmiris de Souza
ContributorsNUNES, Marcus Vinicius Alves
PublisherUniversidade Federal do Pará, Programa de Pós-Graduação em Engenharia Elétrica, UFPA, Brasil, Instituto de Tecnologia
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Source1 CD-ROM, reponame:Repositório Institucional da UFPA, instname:Universidade Federal do Pará, instacron:UFPA
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0018 seconds