Return to search

Remoção dos contaminantes orgânicos β-estradiol e saxitoxinas (STX, Neo-STX e dc-STX) por meio de nanofiltração : avaliação em escala de bancada / Removal of the organic contaminants β-estradiol and saxitoxins (STX, neo-STX and dc-STX) by nanofiltration : bench scale / Removal of the organiccontaminants β-estradiol and saxitoxins (STX, neo-SX and dc-STX) by nanofiltration: bench scale

Submitted by Priscilla Brito Oliveira (priscilla.b.oliveira@gmail.com) on 2009-10-02T20:10:50Z
No. of bitstreams: 1
2008_FlaviaFerreiraAmorim.pdf: 4120631 bytes, checksum: 096fd7d2bfb24128040a5bfdc5005689 (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2009-10-05T14:58:24Z (GMT) No. of bitstreams: 1
2008_FlaviaFerreiraAmorim.pdf: 4120631 bytes, checksum: 096fd7d2bfb24128040a5bfdc5005689 (MD5) / Made available in DSpace on 2009-10-05T14:58:24Z (GMT). No. of bitstreams: 1
2008_FlaviaFerreiraAmorim.pdf: 4120631 bytes, checksum: 096fd7d2bfb24128040a5bfdc5005689 (MD5)
Previous issue date: 2007-11 / O presente trabalho teve como objetivo avaliar a remoção dos contaminantes orgânicos β-
estradiol e das saxitoxinas (STX, dc-STX e Neo-STX) por nanofiltração. A escolha dos
contaminantes foi motivada pela crescente presença desses compostos em mananciais de
abastecimento e o potencial de causar danos à saúde humana mesmo em baixas
concentrações. Pesquisas demonstram que a eficiência de remoção pelo tratamento
convencional não é suficiente para evitar os possíveis efeitos adversos e por isso um
tratamento avançado precisa ser considerado para remoção desses contaminantes.
Os ensaios de nanofiltração foram realizados em um sistema com dispositivo de separação
em membranas de fluxo tangencial, em escala de bancada, com recirculação do
concentrado. A pressão de trabalho aplicada no sistema foi de 689kPa e a velocidade
tangencial constante foi de aproximadamente 0,4m/s. A temperatura da água de
alimentação foi mantida em cerca de 25°C. Foram testados dois tipos de membranas, uma
de acetato de celulose e outra composta de poliamida sobre suporte de polissulfona. Dois
tipos de águas de estudo foram utilizados e, além disso, a influência do valor do pH da
água no processo de remoção dos contaminantes foi avaliada. A água de estudo tipo I
consistia de água deionizada contaminada com β-estradiol em concentração constante de
aproximadamente 10 μg/L. A água tipo II consistia de água deionizada contaminada com
saxitoxinas originadas da cepa de Cylindropermopsis raciborskii. A concentração de
saxitoxinas foi variável, dependendo da concentração resultante do cultivo da
cianobactéria. A quantificação do β-estradiol foi realizada pelo método “Enzyme Linked
Immuno Sorbent Assay” (ELISA) e das saxitoxinas pela Cromatografia Líquida de Alto
Desempenho (CLAE).
Os resultados dos ensaios demonstraram que o mecanismo de adsorção contribuiu para
remoção tanto do β-estradiol, quanto das saxitoxinas. As remoções de β-estradiol foram
maiores para a membrana composta do que para a membrana de acetato de celulose, no
entanto a porcentagem de remoção real não pode ser avaliada, pois não se alcançou o
equilíbrio na remoção. Para as saxitoxinas as remoções foram maiores para a membrana de
acetato de celulose do que para a membrana composta. A elevação do valor de pH
promoveu a redução do fenômeno da adsorção na membrana para os contaminantes
estudados e influenciou positivamente o processo, elevando bastante as eficiências de
remoção de β-estradiol e saxitoxinas. _______________________________________________________________________________ ABSTRACT / The aim of work was to investigate the removal of β-estradiol and saxitoxins (STX, dc-
STX and Neo-STX) by nanofiltration. These contaminants were selected due to its
growing detection in drinking water reservoirs and their potential risk to human health,
even at low concentrations. According to the literature, these substances are only poorly
removed by conventional water and wastewater treatments and it is necessary to consider
advanced treatment processes for efficient removal.
The experiments were carried out in a laboratory scale cross-flow filtration system with
recirculation of the concentrate. The applied pressure was fixed at 689kPa and the constant
cross-flow velocity was 0,4m/s. The temperature of feed solution was kept at about 25°C.
Two nanofiltration membranes, polyamide thin film composite and cellulose acetate, were
tested for the removal of β-estradiol and saxitoxins. The influence of pH solution on
contaminants retention was also examined. Feed water type I was prepared by spiking
estradiol into mili-Q water to make up a solution containing about 10μg/L of β-estradiol.
Feed water type II contained variable concentration of saxitoxins extracted from
Cylindropermopsis raciborskii culture. β-estradiol and saxitoxins concentrations were
quantified by Enzyme Linked Immuno Sorbent Assay (ELISA) method and High
Performance Liquid Cromatography (HPLC), respectively.
The results suggest that the adsorption mechanism contributes for the removal of both β-
estradiol and saxitoxins by nanofiltration. The thin film composite membrane exhibited
higher performance in terms of β-estradiol rejection, but the actual percentage removed
was not obtained because the steady-state was not reached. The cellulose acetate exhibited
a higher performance in terms of the saxitoxins rejection. The adsorption of both β-
estradiol and saxitoxins on the membranes decreased when the pH of the feed water was
increased. At the higher pH value, β-estradiol and saxitoxins rejections also increased.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unb.br:10482/1853
Date11 1900
CreatorsAmorim, Flavia Ferreira
ContributorsBrandão, Cristina Célia Silveira
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UnB, instname:Universidade de Brasília, instacron:UNB
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0018 seconds