Return to search

Estimativa da capacidade de carga e recalque de fundações tipo Alluvial Anker no solo do Distrito Federal

Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2015. / Submitted by Ana Cristina Barbosa da Silva (annabds@hotmail.com) on 2015-06-15T18:31:02Z
No. of bitstreams: 1
2015_FelipeAlvarezZuluaga.pdf: 5691730 bytes, checksum: 82408a48adc9e7e7ea7bb4e456981e88 (MD5) / Approved for entry into archive by Guimaraes Jacqueline(jacqueline.guimaraes@bce.unb.br) on 2015-10-14T15:40:12Z (GMT) No. of bitstreams: 1
2015_FelipeAlvarezZuluaga.pdf: 5691730 bytes, checksum: 82408a48adc9e7e7ea7bb4e456981e88 (MD5) / Made available in DSpace on 2015-10-14T15:40:12Z (GMT). No. of bitstreams: 1
2015_FelipeAlvarezZuluaga.pdf: 5691730 bytes, checksum: 82408a48adc9e7e7ea7bb4e456981e88 (MD5) / A estaca Alluvial Anker é um tipo novo de fundação de pequeno diâmetro caracterizada pela rapidez de execução, com vantagens técnicas e econômicas. Neste trabalho, apresenta-se uma avaliação carga-recalque em estacas deste tipo executadas na Argila Porosa de Brasília, aplicando métodos analíticos e semi-empíricos para o cálculo da capacidade de carga axial e recalque para estaca isolada e em grupo. Para tanto, foi executada uma prova de carga estática em uma estaca isolada sem instrumentação e utilizou-se dos resultados de provas de carga estática em grupos sem contato com solo realizadas por Mendoza (2013) em configurações lineares (2 estacas e 3 estacas) e retangulares (4 estacas, 5 estacas e 6 estacas) com diâmetro de 0,20m e comprimento igual a 8,0m para todas as estacas, incluindo a isolada. A prova de carga executada na estaca isolada forneceu a curva carga-recalque característica de um comportamento de estaca escavada e foi analisada por diferentes metodologias para-se estimar a carga última definida em 424kN. Além disso, tentou-se separar as contribuições de atrito lateral e de ponta com metodologias como Décourt (2008) e Valencia & Camapum (2011), tendo sido estimados valores de 92% para o atrito lateral e 8% para ponta, em média. Os parâmetros geotécnicos utilizados foram obtidos a partir de ensaios in-situ (SPT, SPT-T, DMT e triaxiais), realizados no Campo Experimental da SOLOTRAT Engenharia Geotécnica Ltda., detalhado no trabalho de Mendoza (2013). Os resultados da eficiência experimental foram agrupados de acordo com o tipo de configuração, tendo sido constatada uma eficiência média de 0,87 em configurações lineares, e 0,99 nas configurações retangulares. Verificou-se uma alta dispersão dos resultados na estimativa da capacidade de carga com os métodos semi-empíricos e observa-se a necessidade de se obter fatores empíricos mais apropriados para estimar a capacidade de carga em estacas escavadas do tipo Alluvial Anker, já que as melhores estimativas foram com fatores equivalente à estaca “Raiz”, que levaram a resultados dentro da faixa admissível adotada de ± 20%. A análise de deslocabilidade (recalque) para a estaca isolada e para os grupos foi realizada com metodologias baseadas na teoria da elasticidade e utilizando o software de elementos de contorno DEFPIG “Deformation Analysis of Piles Groups”. / The Alluvial Anker pile is a new type of small diameter bored and injected foundation characterized by the speed of execution, which presents technical and economic advantages. In this work, it will be presented a load-settlement review on piles of this type performed at The Porous Clay of Brasília, where it was applied analytical and semi-empirical methods in order to calculate the axial load capacity and the settlement for single pile and piles groups. To do so, it was performed a static load test in a single pile without instrumentation and it was used the results of static load tests in groups without contact with soil made by Mendoza (2013) in a linear configuration (2 piles and 3 piles) and rectangular (4 piles, 5 piles and 6 piles) with a diameter of 0.20m and a length of 8.0m for all piles, including the single pile. The load test performed on the single pile provided a load-settlement curve characteristic of an excavated behavior, which was analyzed through different methods to estimate the ultimate load defined as 424 kN. In addition, there was an attempt to separate the contributions of shaft resistance and the tip with methodologies such as Décourt (2008) & Camapum Valencia (2011). Those have an estimated value of 92% for the shaft resistance and 8% for the tip, on average. The geotechnical parameters used in the research were obtained from in-situ tests (SPT SPT-T, DMT and triaxial), performed in the Experimental Field of SOLOTRAT Geotechnical Engineering Ltda., detailed in the work of Mendoza (2013). The efficiency of the experimental results is grouped according to the type of configuration that has been noted on an average efficiency of 0.87 in linear configurations and 0.99 in rectangular configurations. There was a high dispersion of the estimated results in terms of the bearing capacity when the semi-empirical methods were used and it is paramount the need of a more appropriate empirical factor to estimate the bearing capacity of Alluvial Anker bored type piles. This occurs because the best estimative were performed by the factors equivalent to a injected type pile, which leads to results within the permissible range adopted of ±20%. The displaceability analysis (settlement) for the single pile and the groups were performed using methodologies based on the Theory of Elasticity and the boundary elements software DEFPIG (Deformation Analysis of Piles Groups).

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unb.br:10482/18593
Date03 March 2015
CreatorsAlvarez Zuluaga, Felipe
ContributorsCunha, Renato Pinto da
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UnB, instname:Universidade de Brasília, instacron:UNB
RightsA concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições:Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data., info:eu-repo/semantics/openAccess

Page generated in 0.0029 seconds