Return to search

Avaliação do reposicionamento mandibular após o uso do Jig de Lucia e da placa oclusal miorrelaxante em pacientes dentados assintomáticos e pacientes dentados com dor nos músculos do sistema mastigatório

Dissertação (mestrado)—Universidade de Brasília, Faculdade em Ciências da Saúde, Programa de Pós-Graduação em Ciências da Saúde, 2002. / Submitted by Patrícia Nunes da Silva (patricia@bce.unb.br) on 2017-04-24T14:35:05Z
No. of bitstreams: 1
2002_LucianaFreitasBezerraSatyroFernandes.pdf: 994952 bytes, checksum: be1c4b6afeeba2b651183556fbdbfd32 (MD5) / Approved for entry into archive by Patrícia Nunes da Silva(patricia@bce.unb.br) on 2017-04-24T14:35:30Z (GMT) No. of bitstreams: 1
2002_LucianaFreitasBezerraSatyroFernandes.pdf: 994952 bytes, checksum: be1c4b6afeeba2b651183556fbdbfd32 (MD5) / Made available in DSpace on 2017-04-24T14:35:30Z (GMT). No. of bitstreams: 1
2002_LucianaFreitasBezerraSatyroFernandes.pdf: 994952 bytes, checksum: be1c4b6afeeba2b651183556fbdbfd32 (MD5) / O presente trabalho teve por objetivo avaliar o reposicionamento mandibular em pacientes assintomáticos e pacientes com sintomatologia dolorosa dos músculos mastigatórios. Com esta finalidade, foi utilizada uma amostra de 24 pacientes, divididos em 2 grupos (I e II). Para o grupo de casos (I), foram selecionados de forma aleatória 12 pacientes do sexo feminino, todos sintomáticos, totalmente dentados. Para o grupo controle (II), indivíduos do sexo feminino totalmente dentados, sem sinais e sintomas de desordem do sistema mastigatório. Para verificar o reposicionamento, após os modelos montados em máxima intercuspidação habitual (MIH) no articulador semi-ajustável, confeccionamos para cada paciente uma plataforma de registro, uma pua, um JIG de Lucia e uma placa oclusal miorrelaxante (POMR).Na plataforma de registro, realizaram-se marcações após o uso do Jig por quinze minutos e a POMR por sete e quinze dias , tendo como ponto de referência a MIH do Paciente. O que pode ser observado foi que o JIG por 15 minutos conseguiu promover um deslocamento mandibular posterior, igual ao uso da placa oclusal miorrelaxante por sete e quinze dias nos dois grupos. A média de deslocamento para o grupo I foi de 1,28mm (s=1.5), para o grupo II a média foi de 0.4mm (s=0.7), nível de significância de 95%.. Os resultados permitem concluir que não houve diferença significativa no reposicionamento final observado após o uso do JIG e da PMOR. / The focus of this study was to mensure the jaw replacement in assymptomatic pacient and pacient with masticatory muscles pain symptomatology. A sample composede of twenty four patients were divided in two groups I and II. The case group(I), was composed by twelve symptomatic, fully teeth , females individuals.The control group (II), was composed by twelve non symptomatic, fully teeth, females individuals. To check the jaw replacement, the cast was mounted on semi-adjustable articulator. Over the cast mounted were manufactured a horizontal plataform , a device worked, a jig of Lucia and a splint. The displacement of the position mandible after the use of the Jig (during 15 minutes) and after the used of splint ( 24 h/ day controlled 15 days). The distances between the marks were measured in a microscopy and the results were statistically analized. The use of the Jig( during 15 minutes), was able to reposit the jaw as the splint( 24 h/ day contolled 15 days) in both group. The replacement average to the group I was 1.28mm and for group II was 0.40mm. The result suggests that jaw replacement after using the Jig and the splint on the two group present similar behavior.

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unb.br:10482/23355
Date January 2002
CreatorsBezerra, Luciana Freitas
ContributorsElias, Antônio Carlos
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UnB, instname:Universidade de Brasília, instacron:UNB
RightsA concessão da licença deste item refere-se ao termo de autorização impresso assinado pelo autor com as seguintes condições: Na qualidade de titular dos direitos de autor da publicação, autorizo a Universidade de Brasília e o IBICT a disponibilizar por meio dos sites www.bce.unb.br, www.ibict.br, http://hercules.vtls.com/cgi-bin/ndltd/chameleon?lng=pt&skin=ndltd sem ressarcimento dos direitos autorais, de acordo com a Lei nº 9610/98, o texto integral da obra disponibilizada, conforme permissões assinaladas, para fins de leitura, impressão e/ou download, a título de divulgação da produção científica brasileira, a partir desta data., info:eu-repo/semantics/openAccess

Page generated in 0.002 seconds