Return to search

Tubos de concreto com adição de resíduos de borracha de pneu

Made available in DSpace on 2014-11-10T11:09:48Z (GMT). No. of bitstreams: 0
Previous issue date: 2012-11-29Bitstream added on 2014-11-10T11:58:02Z : No. of bitstreams: 1
000792656.pdf: 3661871 bytes, checksum: f2c3e3e3d7a967eea0fbfe7baa565706 (MD5) / Os tubos de concreto com diâmetros superiores a 400 mm são utilizados em bueiros, travessias, drenagem pluvial, esgoto sanitário e canalizações de abastecimento; já os resíduos de borracha de pneu estão sendo aplicados com diversas finalidades, como por exemplo: combustível alternativo para as indústrias de cimento, na fabricação de solados de sapato, em borrachas de vedação, dutos pluviais, pisos para quadras poliesportivas, pisos industriais, asfalto-borracha, tapetes para automóveis e diversos tipos de concreto. Os resíduos de borracha de pneu quando adicionadas ao concreto podem melhorar algumas propriedades, tais como: impermeabilidade, flexibilidade, resistência à abrasão e resistência à corrosão. Em outro contexto, a incorporação destes resíduos no concreto surge como uma possibilidade para se atenuar impactos ambientais, ainda mais sabendo que ele é gerado em abundância durante o processo de recauchutagem. Observa-se, no entanto, que a inclusão desse resíduo pode provocar uma diminuição da resistência à compressão axial e do módulo de deformação longitudinal. Esta pesquisa tem por objetivo analisar o comportamento mecânico de protótipo de tubos de concreto feitos com diferentes teores de adições de resíduos de borracha de pneu. tais como: 10 kg/m³, 15 kg/m³, 20 kg/m³, 25 kg/m³ e 30 kg/m³, com base na norma NBR 8890 (ABNT, 2007). Os tubos de concreto possuem 600 mm de diâmetro nominal e 1,5 m de comprimento, sendo destinados aos sistemas de drenagem de águas pluviais. Os tubos de concreto foram submetidos, em escala real, ao ensaio de resistência à compressão diametral e de absorção de água, cujas amostras foram retiradas dos tubos após o ensaio de compressão diametral. Os resultados obtidos no ensaio de compressão diametral foram satisfatórios, todos os traços superaram o valor mínimo da norma, mas os resíduos de borracha de pneu não se comportaram como fibras. O teor de 15 kg ... / The concrete pipes with diameters greater than 400 mm are used in culverts, crossings, rainwater drainage, sanitary sewer and plumbing supply. The tire rubber residues are being applied to various purposes such as: alternative fuel for the cement industry, in the manufacture of shoe soles in rubber seals, rainwater pipes, flooring for sports courts, industrial floors, asphalt-rubber mats for automobiles and various types of concrete. The tire rubber residue, when added to concrete, may improve some properties such as impermeability, flexibility, abrasion resistance and corrosion resistance. In another context, incorporation in the concrete of these residues appears as a possibility to mitigate environmental impacts, especially knowing that it is generated abundantly during the retreading process. It is noted, however, that the inclusion of this residue may lead to a decrease in compressive strength and modulus of elasticity. Based on standard NBR 8890 (ABNT, 2007), this research aims to analyze the mechanical behavior of prototypes of concrete pipes made with different contents of additions of tire rubber residue, such as: 10 kg/m³, 15 kg/m³, 20 kg/m³, 25 kg/m³ and 30 kg/m³. The concrete pipes that were studied had nominal diameter of 600 mm and length of 1.5 m, being intended for drainage systems of rainwater. The concrete pipes in real scale were submitted to the test of diametral compression strength and, after their ruptures, to the water absorption test, which samples were collected from the broken pieces. The results obtained by the diametral compression test were satisfactory since all pipes made with the mixtures exceeded the minimum value of the brazilian standard, but the tire rubber residue did not behave as a fiber. The content of 15 kg of tire rubber residue per cubic meter of concrete was the one who had the best performance. The addition of tire rubber residue had not changed the characteristic of concrete related to ...

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/110504
Date29 November 2012
CreatorsQueiroz, Rodolfo Mori [UNESP]
ContributorsUniversidade Estadual Paulista (UNESP), Melges, José Luiz Pinheiro [UNESP], Akasaki, Jorge Luís [UNESP]
PublisherUniversidade Estadual Paulista (UNESP)
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format90 f. : il. color.
SourceAleph, reponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP
Rightsinfo:eu-repo/semantics/openAccess
Relation-1, -1, -1

Page generated in 0.0026 seconds