Return to search

Análise experimental de diafragmas piezelétricos comerciais para detecção de dano estrutural baseada na impedância eletromecânica / Experimental analysis of commercial piezoelectric diaphragms for structural damage detection based on the electromechanical impedance

Submitted by EVERALDO SILVA DE FREITAS null (everaldo.freitas@gmail.com) on 2016-07-03T18:42:32Z
No. of bitstreams: 1
Dissertação_Mestrado_Everaldo_Freitas_2016_final.pdf: 3897384 bytes, checksum: 5c9536e39331c3a9d0ddfa1752cc723a (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-07-07T16:33:04Z (GMT) No. of bitstreams: 1
freitas_es_me_bauru.pdf: 3897384 bytes, checksum: 5c9536e39331c3a9d0ddfa1752cc723a (MD5) / Made available in DSpace on 2016-07-07T16:33:04Z (GMT). No. of bitstreams: 1
freitas_es_me_bauru.pdf: 3897384 bytes, checksum: 5c9536e39331c3a9d0ddfa1752cc723a (MD5)
Previous issue date: 2016-05-30 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Esta dissertação de mestrado apresenta uma análise experimental da viabilidade do uso dos diafragmas piezelétricos comerciais de baixo custo (comumente conhecidos como buzzers) em sistemas de monitoramento de integridade estrutural (SHM – Structural Health Monitoring) baseados na técnica da impedância eletromecânica (E/M). Esse tipo de aplicação tem recebido uma atenção especial nas últimas décadas por se basear no uso de transdutores piezelétricos pequenos e leves que operam simultaneamente como sensores e atuadores. Foram realizados vários testes em barras de alumínio utilizando diafragmas de diversos tamanhos; as assinaturas de impedância elétrica e os índices de dano foram comparados com os obtidos usando uma cerâmica convencional de PZT (Pb-lead Zirconate Titanate – titanato zirconato de chumbo), que é o transdutor mais comumente utilizado nessa aplicação. Os danos estruturais foram simulados utilizando-se massas metálicas (porcas de parafuso), as quais foram fixadas nas barras com cola a base de cianoacrilato. Quatro tipos de experimentos foram realizados para fins de comparação: estimação da sensibilidade dos transdutores utilizando método da quebra do grafite (PLB – Pencil Lead Break – quebra do grafite); comparação dos índices de dano RMSD (root mean square deviation – desvio da raiz média quadrática) e CCDM (correlation coefficient deviation metric – métrica do desvio do coeficiente de correlação), calculados a partir das assinaturas de impedância; avaliação dos efeitos da temperatura; e a avaliação da reprodutibilidade dos resultados a longo prazo. Os resultados indicaram que a cerâmica convencional de PZT e um diafragma de tamanho semelhante apresentam características bem próximas em relação à reprodutibilidade dos resultados, sensibilidade ao dano e aos efeitos de temperatura, o que leva a conclusão de que os diafragmas são viáveis para sistemas de SHM baseados na impedância E/M. / This dissertation presents an experimental analysis of the viability of low-cost commercial piezoelectric diaphragms (commonly known as buzzers) in structural health monitoring (SHM) systems based on the electromechanical impedance (EMI) technique. This application has received special attention in recent decades because it is based on the use of small, lightweight piezoelectric transducers operating as both sensors and actuators. Several tests were carried out on aluminum bars using diaphragms of different sizes; the electrical impedance signatures and damage indices were compared with those obtained using a conventional PZT (Pb-Lead Zirconate Titanate) ceramic, which is the most commonly employed transducer in this application. Structural damage was simulated using metallic bolts (steel nut), which were fixed in the bars using cyanoacrylate glue. Four types of experiments were carried out for comparison between the two transducers: sensitivity estimation using the pencil lead break (PLB) method, analysis of the feasibility to detect structural damage using conventional impedance signatures and damage indices, analysis of temperature effects, and determination of the long-term reproducibility of the results. The results indicated that conventional PZT ceramics and diaphragms with similar size exhibit very close characteristics in relation to reproducibility, sensitivity to damage and temperature effects, which leads to the conclusion that the piezoelectric diaphragms are feasible in SHM systems based on the EMI method. / FAPESP: 2015/02500-6

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/141447
Date30 May 2016
CreatorsFreitas, Everaldo Silva de [UNESP]
ContributorsUniversidade Estadual Paulista (UNESP), Baptista, Fabrício Guimarães [UNESP]
PublisherUniversidade Estadual Paulista (UNESP)
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Sourcereponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP
Rightsinfo:eu-repo/semantics/openAccess
Relation600

Page generated in 0.0029 seconds