Otimização e validação de método cromatográfico para determinação de 17 'beta'- estradiol, estrona e estriol em solo tratado com esterco animal e iodo de ETE

Made available in DSpace on 2014-06-11T19:29:07Z (GMT). No. of bitstreams: 0
Previous issue date: 2012-01-13Bitstream added on 2014-06-13T18:38:47Z : No. of bitstreams: 1
canaver_eg_me_araiq.pdf: 833382 bytes, checksum: 685c500a01dea9d813121ce544983ebe (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / A crescente preocupação com o possível impacto ambiental provocado por micropoluentes orgânicos com o potencial de causar efeitos adversos à saúde em humanos e animais selvagens tem levado a comunidade científica a pesquisar e desenvolver métodos analíticos na determinação destas substâncias, em especial alteradores endócrinos presentes em matrizes ambientais, tais como águas superficiais e subterrâneas e efluentes de ETEs. Porém, poucos estudos em solo têm sido feitos. No presente trabalho, pretende-se otimizar e validar método para determinação de estrógenos em solos tratados com esterco bovino e lodo de ETE, utilizando-se a extração sólido-líquido por banho de ultrassom seguido de extração em fase sólida (SPE) e a dispersão de matriz em fase sólida (MSPD), no intuito de avaliar os principais fatores que influenciam esse processo e identificar as melhores condições de recuperação. Os parâmetros mais utilizados no processo de validação analítica incluem os limites de detecção e quantificação, seletividade, linearidade ou faixa de trabalho, precisão e exatidão. Foram analisadas matrizes de solo da cidade de Araraquara-SP e lodo biológico proveniente da Estação de Tratamento de Esgoto de Jaú-SP, fortificadas com hormônios 17β- estradiol (E2), estrona (E1) e estriol (E3), sendo a determinação analítica feita por HPLC/UV/Fluorescência. O método foi validado de acordo com os seguintes parâmetros: faixa de trabalho, obtida a partir de curvas analíticas entre (0,8 a 10,0μg mL-1 para (E1) e (E3) e 32,0 a 400,0(ng mL-1) para o (E2); seletividade (ausência de interferentes nas amostras); exatidão (recuperação: 46-94%); precisão (CV: 1-15%); e limites de quantificação (0,1 μg g-1 para (E2) e 2,5 μg g-1 para (E1) e (E3)) para os estrógenos estudados. O método proposto permitiu análise simultânea dos estrógenos... (Resumo completo, clicar acesso eletr / The growing concern about possible environmental impacts caused by organic micropollutants with the potential to cause adverse health effects in humans and wildlife has led the scientific community to research and develop analytical methods in determining these substances, especially endocrine disruptors present in environmental matrices such as surface and groundwaters and effluent from sewage treatment plants. However, few studies have been done in soil. In this paper, we intend to optimize and validate the method for determination of estrogens in soils treated with manure and sludge STS, using the solid-liquid extraction ultrasonic bath extraction followed by solid phase extraction (SPE) and the matrix solid phase dispersion (MSPD), in order to evaluate the main factors influencing this process and better recovery. The parameters commonly used in the validation process include the analytical limits of detection and quantification, selectivity, linearity and working range, precision and accuracy. Matrices of soil were analyzed from the city of Araraquara-SP and biological sludge from the Sewage Treatment Station Jau- SP, fortified with hormones 17β-estradiol (E2), estrone (E1) and estriol (E3), and analytical determination made HPLC/UV/Fluorescence. The method was validated according to the following parameters: working range, obtained from analytical curves between (0,8 and 10,0 μg mL-1 for (E1) and (E3), and 32,0 and 400,0 (ng mL-1) to (E2), selectivity (no interferences in the samples); accuracy (recovery: 46-94%), precision (CV: 1-15%) and limits of quantification (0,1μg g- 1 for (E2) and 2,5 μg g-1 for (E1) and (E3)) for the estrogens studied. The proposed method allows simultaneous analysis of estrogens... (Complete abstract click electronic access below)

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/97797
Date13 January 2012
CreatorsCanaver, Eduardo Garbulho [UNESP]
ContributorsUniversidade Estadual Paulista (UNESP), Marchi, Mary Rosa Rodrigues de [UNESP]
PublisherUniversidade Estadual Paulista (UNESP)
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format82 f. : il.
SourceAleph, reponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP
Rightsinfo:eu-repo/semantics/openAccess