Return to search

Estudo do comportamento eletroquímico de alguns agentes antifúngicos utilizando polarografia de pulso diferencial e voltametria de redissolução catódica

Made available in DSpace on 2014-06-11T19:29:09Z (GMT). No. of bitstreams: 0
Previous issue date: 1999-10-13Bitstream added on 2014-06-13T20:59:16Z : No. of bitstreams: 1
pereira_fc_me_araiq.pdf: 556953 bytes, checksum: 7bcebc47bc5a71dfcab59fba15f66e20 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O comportamento voltamétrico de dois agentes antifúngicos denominados de Clotrimazol e Miconazol foi investigado em meio hidrometanólico sobre eletrodo de mercúrio. Clotrimazol e miconazol são reduzidos em potencial bastante negativo em solução tampão B-R pH > 6 através da transferência reversível de 1 elétron à ligação C-Cl, cujo mecanismo de redução foi investigado através de PPD e VC. Para a determinação destes compostos em meio aquoso, recomenda-se a adição de 0,001% de Triton X-100 através da qual obteve-se uma curva de calibração linear entre 5x10- 6 a 2,8x10- 4 mol.L- 1 para clotrimazol em solução tampão fosfato pH 6,9 e para miconazol 192,0 a 718,5 ng.mL- 1 em solução tampão B-R pH 8,0 Um novo método para determinação indireta de clotrimazol através da técnica polarográfica de pulso diferencial foi investigado através da reação de derivatização do fármaco com o corante reativo Procion Red HE-3B (RR 120). O produto da reação entre a função clorotriazina do corante e clotrimazol... / Clotrimazole is reduced at mercury electrode above pH 6 involving a reversible one-electron process. The electrodic process presents a large contribution of the adsorption effects. For the differential pulse polarographic determination is recommended the addition of Triton X-100, which promotes a linear calibration curve from 5x10- 6 mol.L- 1 to 2,8x10- 4mol. L- 1. In addition, clotrimazole can be determined by cathodic stripping voltammetry at 5ng.mL- 1 level when pre-accumulated for 1 min at an accumulation potential of -0,2V. The proposed method have shown a linear calibration curve from 103 to 345ng.mL- 1 and can be applied successfully for the determination of the clotrimazole in commercial formulations. Interaction of the clotrimazole with reactive dye Procion Red HE-3B (RR 120) was investigated in aqueous solution by differential pulse polarography. The clotrimazole derivatized with the reactive dye in B-R buffer (pH 2) yielded a sensitive polarographic response at -0,38V (vs Ag/AgCl). Analytical parameters such as pH, buffer compositions, temperature, reaction time and concentration of dye have been optimised. Linear calibration curves for clotrimazole have been construted from 10-34 μg.mL- 1 using 1x10- 4 mol.L- 1 of the dye at room temperature. The method has been applied to the determination of clotrimazole in pharmaceutical preparations...(Complete abstract, click electronic access below)

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unesp.br:11449/97874
Date13 October 1999
CreatorsPereira, Francisco Claudece [UNESP]
ContributorsUniversidade Estadual Paulista (UNESP), Zanoni, Maria Valnice Boldrin [UNESP]
PublisherUniversidade Estadual Paulista (UNESP)
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format189 f.
SourceAleph, reponame:Repositório Institucional da UNESP, instname:Universidade Estadual Paulista, instacron:UNESP
Rightsinfo:eu-repo/semantics/openAccess
Relation-1, -1

Page generated in 0.0027 seconds