Return to search

Colunas esbeltas de pequeno diametro mistas de aço preenchidas com concreto em situação de incendio / Slender concrete filled steel columns with diameter in fire condition

Orientador: Armando Lopes Moreno Junior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-11T16:14:42Z (GMT). No. of bitstreams: 1
Gomide_KleberAparecido_M.pdf: 5190586 bytes, checksum: 23856ed638614979a44be4f707ac4ddb (MD5)
Previous issue date: 2008 / Resumo: Neste trabalho será abordado o comportamento estrutural de colunas esbeltas de pequeno diâmetro mistas de aço preenchidas com concreto em situação de incêndio. As colunas mistas vêm sendo largamente utilizadas em edifícios altos,
principalmente, em países europeus, americanos e asiáticos. No Brasil, seu uso, vem sendo difundido na engenharia nacional. As colunas mistas preenchidas são reconhecidas por um melhor comportamento estrutural, em situação ambiente, devido ao incremento de resistência e rigidez, se comparados às colunas de aço sem preenchimento. Além disso, nota-se, um melhor comportamento dessas seções em situação de incêndio, pois, o núcleo de concreto funciona como um dissipador de calor, resfriando a seção e, com isso, aumentando sua resistência em situação de incêndio. Nesse contexto, este trabalho compreende um estudo teórico, a partir da literatura existente e, um estudo experimental, abordando o comportamento de colunas esbeltas de pequeno diâmetro mistas de aço preenchidas com concreto em situação de incêndio, utilizando perfis de aço laminados de diferentes diâmetros, preenchidas com concreto de resistência usual e, submetidos a diferentes níveis de carregamentos axiais, a saber, 30, 50 e 70% da carga última de ruptura. Além disso, serão analisadas, também, seções sem preenchimento de concreto, com as mesmas variáveis adotadas para as seções preenchidas com o propósito de obter referências para o estudo e, avaliar o ganho de resistência, em situação ambiente e, em incêndio. Os dados obtidos são analisados, fazendo-se comparações desses resultados aos resultados teóricos obtidos por meio do EUROCODE 4 (prEN 1994-1-2:2002) e, também, com resultados disponíveis na literatura técnica. Ao final do trabalho, verificouse,
um aumento considerável na resistência ao fogo das colunas mistas preenchidas ao compará-las às seções sem preenchimento e, um decréscimo nessa resistência com o incremento nos níveis de carregamento / Abstract: This paper will be examine the structural behaviour of slender concrete filled steel columns with small diameter in fire condition. This columns have been widely used in tall buildings, mainly in European, Asian and American countries. In Brazil, its use, is being spread on the national engineering. This columns are recognized by a better structural behaviour in room temperature due to increase in strength and stiffness when compared to the columns of steel without filling. Moreover, there is a better behaviour of those sections in fire condition, therefore, the core of concrete acts as a heat sink of heat decreasing the temperature of section, thereby increasing their resistance to a fire. In that context, this paper includes a theoretical study, from the existing literature, and na experimental study, addressing the behaviour of slender concrete filled steel columns with small diameter in fire conditiom, using profiles of different diameters of rolled steel, filling with usual resistance concrete, subject to different levels of axial loads, namely, 30, 50 and 70% of the load last of collapse. Moreover, will be examined, also, without filling sections of concrete, with the same variables taken to sections filled with the purpose to get references for the study and evaluate the gain of strength in room temperature, and in fire condition. The data are analyzed, making comparisons to those results to the results obtained from the theoretical by EUROCODE 4 (prEN 1994-1-2:2002) and also with results available in technical literature. At the end of the paper, there was a considerable increase in resistance to fire the concrete filled steel columns to compare them to sections without filling, and a decrease in this resistance with the increase in the levels of loading / Mestrado / Estruturas / Mestre em Engenharia Civil

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/258261
Date31 July 2008
CreatorsGomide, Kleber Aparecido
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Moreno Junior, Armando Lopes, 1964-, Junior, Armando Lopes Moreno, Requena, João Alberto Venegas, Silva, Valdir Pignatta e
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Civil, Arquitetura e Urbanismo, Programa de Pós-Graduação em Engenharia Civil
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format246p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0022 seconds