Estudo da conexão da usina de Belo Monte ao SIN através da alternativa de transmissão em meia onda / Half wavelegth transmission lines connecting Belo Monte power plant to the Brazilian interconnected system

Orientador: Luiz Carlos Pereira da Silva / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-24T07:39:20Z (GMT). No. of bitstreams: 1
Gomes_LeandroCostaFerreira_M.pdf: 6148500 bytes, checksum: bf5007e253bf40d848b0494ce01ead56 (MD5)
Previous issue date: 2014 / Resumo: O presente trabalho está inserido num contexto de busca de novas fontes de energia elétrica e de aproveitamento de grandes potenciais energéticos localizados distantes dos principais centros de carga. Para estes, alternativas não convencionais de transmissão também são exigidas, nas quais se insere a transmissão em linhas de pouco mais de meio comprimento de onda, distância de pouco mais de 2500km no sistema brasileiro à 60Hz. Como este tipo de transmissão nunca foi implementado, trata-se de uma proposta inovadora, pouco explorada e que exige ensaios elementares para testar-se a viabilidade, vantagens e desvantagens frente a outras alternativas de transmissão de energia elétrica. Esta dissertação visa investigar alguns aspectos referentes à tal método de transmissão de grandes montantes de potência em distintos cenários de interligação entre as regiões Norte e Sudeste do Brasil do SIN (sistema interligado nacional). Três distintos corredores compostos por linhas de pouco mais de meio comprimento de onda foram ensaiados. Inseridos conectando a usina de Belo Monte no Pará a Assis-SP na rede de 500kV, percorrendo 2664 km. Cada um dos corredores é composto por: três linhas de 800 kV e 4846 MW de potência característica (SIL); um segundo com duas das mesmas linhas de 800kV e um terceiro com duas linhas de 1000 kV e 8100 MW de potência característica. Cada aspecto é ensaiado em seis diferentes situações de carregamento do SIN e de fluxo de potência pelo corredor, abrangendo cenários de alto, médio e baixo carregamento das linhas assim como mudanças no sentido do fluxo entre Norte e Sudeste. Dentre os aspectos abordados estão: a avaliação e redução das perdas manipulando a potência característica operacional das linhas; o controle do carregamento do corredor através do uso de transformadores defasadores não convencionais; a inserção de cargas e geração em pontos intermediários deste e o controle do fluxo de potência reativa. Por fim, o estudo não aborda aspectos transitórios e é realizado com o auxílio do ANAREDE, software elaborado pelo CEPEL / Abstract: This work is placed in a search for new sources of power and exploitation of large energy potential located far from major load centers. For the second scenarios, alternate non-conventional transmission are also required, in which half wavelength transmission lines are inserted, resulting in a distance of just over 2500km for the 60Hz brazilian electrical system. Since this type of transmission has never been implemented, it is an innovative solution and few explored, requiring elementary studies to test the feasibility, advantages and disadvantages compared to other alternatives for bulk electric power transmission. This thesis aims to investigate some aspects related to such transmission method for large amounts of power into distinct scenarios of interconnection between the North and Southeast of Brazil's SIN (Brazilian National grid). Corridors consisting of three distinct lines of just over half wavelength were tested. Inserted connecting Belo Monte hydro power plant in Para to Assis in São Paulo through the 500kV network, covering 2664 km, each corridor is composed: by three lines of 800 kV and 4846 MW of Surge Load Impedance (SIL), the second one by two of the same 800kV lines and a third by two lines of 1000 kV and 8100 MW SIL. Each aspect is tested in six different SIN load situations and power flowing through the corridor, covering scenarios of high, medium and low lines loading as well as changes in flow direction between North and Southeast. Among the issues tackled are: evaluation and reduction of losses by manipulating operating lines SIL; line load controlling using non-conventional phase shift transformers; inserting loads and generation at intermediate points of the lines and control of reactive power flow. Finally, the study does not handle with transient aspects and is accomplished with the aid of ANAREDE, software developed by CEPEL / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/259505
Date24 August 2018
CreatorsGomes, Leandro Costa Ferreira, 1986-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Silva, Luiz Carlos Pereira da, 1972-, Paz, Marcos de Araujo, Almeida, Madson Cortes de
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Elétrica e de Computação, Programa de Pós-Graduação em Engenharia Elétrica
Source SetsIBICT Brazilian ETDs
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format118 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0298 seconds