Análise do impacto da proteção antiilhamento na estabilidade de geradores conectados via inversores / Stability analysis of inverter-based distributed generators with antiislanding protection

Orientador: Walmir de Freitas Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Elétrica e de Computação / Made available in DSpace on 2018-08-16T21:04:55Z (GMT). No. of bitstreams: 1
Ricciardi_TiagoRodarte_M.pdf: 3291776 bytes, checksum: c647c3c5eaa394835294087b10e89863 (MD5)
Previous issue date: 2010 / Resumo: O uso de geradores conectados via inversores em redes de distribuição de energia elétrica tem aumentado consideravelmente nos últimos anos em razão dos avanços obtidos nas tecnologias de células a combustível e fotovoltaicas bem como de microturbinas e turbinas eólicas. Nesse contexto, a utilização de sistemas de proteção antiilhamento no ponto de conexão do gerador com a rede elétrica é uma das exigências previstas nos principais guias técnicos empregados pelas concessionárias. Ilhamento ocorre quando uma parte da rede de distribuição torna-se eletricamente isolada da fonte de energia principal (subestação), mas continua a ser energizada por geradores distribuídos conectados no subsistema isolado. No caso particular dos geradores conectados via inversores, os principais dispositivos utilizados comercialmente para fornecer proteção antiilhamento são baseados no conceito de realimentação positiva, cuja idéia básica é empregar um dos parâmetros que definem a tensão terminal do gerador como sinal de realimentação positiva no seu sistema controle. Caso o gerador esteja conectado ao sistema de distribuição, a realimentação positiva não consegue, a priori, desestabilizar o gerador. Por outro lado, caso o gerador torne-se ilhado, a realimentação positiva fará com que o gerador se torne instável e, por conseguinte, a situação de ilhamento pode ser rapidamente detectada por relés de sub/sobre tensão e/ou sub/sob freqüência. Visto que tal esquema de proteção esforça-se para desestabilizar o gerador independentemente da ocorrência ou não de ilhamentos, é fundamental desenvolver ferramentas para analisar a estabilidade de redes com múltiplos geradores equipados com proteção antiilhamento via realimentação positiva. O objetivo desta dissertação de mestrado foi desenvolver uma série de modelos linearizados no espaço de estados para representar os principais dispositivos de proteção antiilhamento existentes comercialmente a fim de investigar a estabilidade frente a pequenas perturbações de sistemas de distribuição de energia elétrica com múltiplos geradores conectados via inversores utilizando-se análise modal / Abstract: The usage of inverter-based generators connected directly to electric Power distribution systems has considerably increased in recent years due to the technological advances of fuel and photovoltaic cells as well as microturbines and wind turbines. In this context, the usage of anti-islanding protection devices at the interconnection point is required by the main technical guides utilized by the utilities. Islanding occurs when a portion of the distribution system becomes electrically isolated from the remainder of the power system, yet continues to be energized by distributed generators. In the case of inverter-based generators, the main devices commercially employed to supply anti-islanding protection are based on the positive feedback concept. These methods use the deviations of voltage frequency and/or magnitude from normal values as positive feedback signals into the control system to influence the operation of inverterbased distributed generators. If the generator is connected to a strong utility system, in priori, the destabilizing force of the positive feedback has a negligible impact and the generator can operate without difficulties. On the other hand, when the generator is islanded, the positive feedback can destabilize the generator easily. Such distinctively different generator behaviors facilitate the detection of islanding conditions by using under/over voltage and frequency relays. Since the positive feedback scheme is a destabilizing force, the impact of this scheme on the stability of system with multiples inverter-based generators is of concern. If the positive feedback gain is too high, the generator may become unstable even if it is connected to the main supply system. Thus, the objective of this master thesis is to develop several small-signal models to investigate the stability of distribution network with multiple inverter-based generators with positive feedback anti-islanding protection by using modal analysis / Mestrado / Energia Eletrica / Mestre em Engenharia Elétrica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/259992
Date16 August 2018
CreatorsRicciardi, Tiago Rodarte, 1986-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Freitas Filho, Walmir de, 1971-, Filho, Walmir de Freitas, Coelho, Ernane Antônio Alves, Almeida, Madson Cortes de
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Elétrica e de Computação, Programa de Pós-Graduação em Engenharia Elétrica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format134 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess