Return to search

Modelo de linha de transmissão polifasica utilizando quase-modos

Orientador: Jose Pissolato Filho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-24T23:53:17Z (GMT). No. of bitstreams: 1
Tavares_MariaCristinaDias_D.pdf: 13944555 bytes, checksum: 27b287b7a43399cedc5cf3b43c4c3e06 (MD5)
Previous issue date: 1998 / Resumo: Este trabalho apresenta novos modelos para representar linhas de transmissão em estudos de transitórios eletromagnéticos, incluindo a dependência com a freqüência dos parâmetros longitudinais. Os parâmetros são modelados no domínio dos modos através de cascata de circuitos 1ts. A característica básica do modelo é aproveitar as propriedades geométricas das linhas e utilizar matrizes de transformação fase-modo reais, função da geometria das torres. Essas matrizes são utilizadas para todo o espectro de freqüência dos fenômenos de manobras e chaveamentos típicos. Os modelos são apresentados para a linha trifásica simples, trifásica circuito duplo, corrente contínua e hexafásica. Para a linha de corrente contínua com plano de simetria vertical a solução é exata, mas para as demais, caso haja transposição, as matrizes reais conduzem a modos exatos. Porém, se as linhas não forem transpostas, a transformação não desacopla totalmente os modos, produzindo quase-modos. O modelo para a linha trifásica simplesé aplicado a uma linha de 440 kV da CESP. Inicialmente é verificada a validade do modelo e quantificada a sua imprecisão. A seguir são efetuados algumas simulações com o ATP para o modelo proposto e dois modelos internos com dependência com a freqüência com o intuito de comparação. Foi realizada também uma análise no domínio da freqüência entre os autovetores exatos da linha e os vetores reais do modelo. ...Observação: O resumo, na íntegra, poderá ser visualizado no texto completo da tese digital / Abstract: In the present work new models to represent transmission tines including the frequency dependency of longitudinal parameters are presented. The parameters are represented in the mode domain through a cascade of 1tcircuits. The model characteristic is to take advantage of the tine geometric properties and use real phase-mode transformation matrices; the function of the tower geometry. These matrices are used for typical switching transients with large frequency spectrums. The models are presented for single three-phase, double three-phase, dc and six-phase transmission tines. For dc tines with a vertical syrnmetryplane the solution is exact and for the others, if they are transposed, the real matrices lead to exact modes. However, if the tines are non-transposed, the real transformation does not completely uncouple the modes, creating quasi-modes. The single three-phase model is applied to a 440 kV transmission tine. Initially, the model validity is verified and its imprecision if quantified. Then some transient simulations are performed with ATP using the proposed model and two internal ATP frequency dependent model, called the Semlyen and JMarti models. ...Note: The complete abstract is available with the full electronic digital thesis or dissertations. ...Note: The complete abstract is available with the full electronic digital thesis or dissertations / Doutorado / Doutor em Engenharia Elétrica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/260913
Date26 June 1998
CreatorsTavares, Maria Cristina Dias, 1962-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Pissolato Filho, José, 1951-, Filho, Jose Pissolato
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Elétrica e de Computação, Programa de Pós-Graduação em Engenharia Elétrica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format255f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0018 seconds