Return to search

Avaliação termoeconomica do sistema de cogeração da usina vale do rosário

Orientador: Silvia Azucena Nebra / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Mecanica / Made available in DSpace on 2018-07-25T02:14:23Z (GMT). No. of bitstreams: 1
BarredadelCampo_EduardoRafael_D.pdf: 17760825 bytes, checksum: e615b8119930215374ead3ca1bc91ca7 (MD5)
Previous issue date: 1999 / Resumo: No presente trabalho avalia-se um sistema de cogeração de uma usina de açúcar e álcool onde se faz uma análise termoeconômica de dito sistema para três safras, 1996, 1997 e 1998, através da Teoria do Custo Exergético. Previamente à análise termoeconômica foi feita uma análise exergética do sistema, determinando-se as eficiências de Primeira e Segunda Lei para os
principais equipamentos da planta, assim como são determinados alguns índices caracteristicos de sistemas de cogeração, baseados na primeira lei da termodinâmica, comparando este com outras plantas de cogeração. O objetivo fundamental da avaliação foi o de captar os custos dos principais fluxos do sistema e em específico dos produtos (potência elétrica e vapor de processo) considerando os custos de ínstalação da planta de cogeração, como se fosse um sistema novo, que será amortizado em 15 anos com uma taxa de juros de 12 % ao ano. São feitas diferentes considerações: i) são determinados para os custos dos fluxos do sistema, que parcela desses custos é devida aos custos dos insumos (água de reposição e bagaço), ii) é avaliada a influência do aumento da eficiênciadas caldeiras, considerando diferentes preços do bagaço, iii) na safra 97 e 98 foram feitas três abordagens em relação à perda de vapor à atmosfera / Abstract: In the present work, a cogeneration system of a sugar-alcohol cane mill isevaluated. Using the Exergetic Cost Theory, a thermoeconomic analysis is made for three crops, corresponding to the years of 1996, 1997 and 1998. Previusly, na energetic and exergetic analysis was made, determining the first and second law equipment' s efficiencies and also some performace criteria
of the overall system. This performance criteria are compared with characteristic values of other cogeneration systems. The fundamental objective ofthe evaluation was to get the costs of the principal fluxes of the system and specifically of the prodects: electric and mechanical power, and process heat. The cost considered were the installation, capital and maintenance costs, the cost of resources: water and bagasse, were also considered. A capital recovery period of 15 years was assumed, with a discount rate of 12 %. Different considerations were made: i - influence of the resource costs of the fluxes were calculated considering only this part of the total costs, ii - influence of the boiler efficiency,considering different prices for the bagasse, iii - in the crops of 1997 and 1998, three different treatments were made for the steam lost to the atmosphere / Doutorado / Termica e Fluidos / Doutor em Engenharia Mecânica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/265538
Date19 May 1999
CreatorsBarreda del Campo, Eduardo Rafael
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Nebra, Silvia Azucena, 1943-, Macedo, Isaias de Carvalho, Jr, Silvio de Oliveira, Beltran, Jorge Isaias Llagostera, Silva, Arnaldo Walter da
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Mecânica, Programa de Pós-Graduação em Engenharia Mecânica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format280 p., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess