Otimização de ciclos de refrigeração para a produção de gás natural liquefeito / Optimization of refrigeration cycles for the production of liquefied natural gas

Orientador: José Vicente Hallak d'Angelo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Química / Made available in DSpace on 2018-08-25T15:12:16Z (GMT). No. of bitstreams: 1
Andrade_ThallesAllan_M.pdf: 2702197 bytes, checksum: 32c6cee79361c26e4489867146b0682e (MD5)
Previous issue date: 2014 / Resumo: Por se tratar de um combustível fóssil menos emissor de gás carbônico ao meio ambiente do que outros combustíveis, a demanda mundial de gás natural para sua utilização como fonte energética tem aumentado nos últimos anos. No entanto, quando a quantidade requerida de importação do gás natural é alta e é grande a distância entre os países fornecedores e compradores, o transporte do gás por meio de gasodutos torna-se inviável, acarretando na necessidade de produção de gás natural liquefeito. Ao se liquefazer a uma temperatura próxima a -160 °C, o volume do gás natural é reduzido em até 600 vezes, permitindo ser transportado a grandes distâncias por meio de embarcações especiais. Na liquefação do gás natural estão envolvidos ciclos de refrigeração que podem ser utilizados por diferentes rotas. Os principais tipos de ciclo de refrigeração são o ciclo de compressão de vapor e o ciclo de absorção. Nesse trabalho, foram simulados no programa Aspen HYSYS, versão 7.3, os ciclos cascata e APCI para a produção de GNL, que utilizam ciclos de refrigeração por compressão de vapor. O coeficiente de desempenho global do ciclo APCI alcançado com as simulações foi maior que o do ciclo cascata: 1,690 contra 0,839. Em seguida, um dos subciclos de compressão de vapor envolvidos no ciclo APCI foi substituído por um subciclo de absorção de efeito simples, utilizando-se diferentes combinações de pares refrigerante/absorvente (NH3/H2O, NH3/DMF, R22/DMF e R134a/DMF). O ciclo com o par NH3/DMF foi aquele com os melhores resultados para o coeficiente de desempenho. Finalmente, foram realizadas duas etapas de otimização dos ciclos propostos: uma delas através da maximização do COP dos ciclos de refrigeração e outra baseada na minimização dos custos dos processos, referentes aos custos dos principais equipamentos envolvidos. A maximização conseguiu atingir COP igual a 2,062 para o ciclo cascata e 2,505 para o ciclo APCI. Dentre os pares avaliados no ciclo APCI modificado, o par NH3/DMF manteve-se com o melhor COP do subciclo de absorção. Na minimização dos custos, obteve-se o custo dos equipamentos de US$ 4,1 milhões para o ciclo cascata e US$ 14,3 milhões para o ciclo APCI original. Em relação aos pares do ciclo APCI modificado, o par NH3/H2O apresentou os menores custos, tanto antes quanto depois da otimização, alcançando US$ 9,8 milhões / Abstract: Because it is a fossil fuel that emits less carbon dioxide to the environment than other fuels, worldwide demand for natural gas for use as energy source has increased in recent years. However, when the required amount of imports of natural gas is high and there is a great distance between suppliers and buyers of the gas, the gas transportation through pipelines it is not feasible, resulting in the need to produce liquefied natural gas (LNG). When the gas reaches a temperature close to -160 ° C, its volume is reduced by up to 600 times, allowing the liquefied natural gas to be transported over long distances through special ships. Liquefaction of natural gas involves refrigeration cycles that may be used by different routes. The main types of refrigeration cycle are the cycle vapor compression cycle and absorption cycle. In this study, it was simulated, on Aspen HYSYS, version 7.3, the cascade and the APCI cycles, to roduce LNG using vapor compression refrigeration cycles. The overall COP for the APCI cycle achieved after the simulations was greater than that the cascade cycle coefficient of performance: 1.690 against 0.839. Then, a vapor compression subcycle involved in the APCI cycle has been replaced by a single-effect absorption cycle, using different combinations of refrigerant/absorbent pairs (NH3/H2O, NH3/DMF, R22/DMF and R134a/DMF). The modified APCI cycle using the pair NH3/DMF was the one with the best results for the coefficient of performance. Finally, two stages of the proposed optimization cycles were performed: one through the maximization of the COP of the refrigeration cycles and one based on the minimization of process costs, regarding the costs of major equipment involved. Maximization has achieved COP equal to 2.062 for the cascade cycle and 2.505 for the APCI cycle. Among the pairs evaluated in the modified APCI cycle, the pair NH3/DMF remained with better COP of the absorption subcycle. In minimizing of costs, it was obtained the equipment cost of $ 4.1 million for cascade cycle and $ 14.3 million for the original APCI cycle. Regarding the modified APCI cycle, the pair NH3/H2O had showed the lowest cost, both before and after optimization, reaching $ 9.8 million / Mestrado / Engenharia Química / Mestre em Engenharia Química

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/266096
Date25 August 2018
CreatorsAndrade, Thalles Allan, 1988-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, D'Angelo, José Vicente Hallak, 1967-, Zemp, Roger Josef, Gallo, Waldyr Luiz Ribeiro
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Química, Programa de Pós-Graduação em Engenharia Química
Source SetsIBICT Brazilian ETDs
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format123 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0026 seconds