Return to search

Separação cromatografica do farmaco rolipram utilizando fase estacionaria O, O'-bis [4-terc-butilbenzoil]-N, N'-dialil-L-tartardiamida / Chromatographic separation of rolipram using O, O'-bis [4-tert-butylbenzoyl]-N, N'-diallyl-L-tartardiamide

Orientador: Cesar Costapinto Santana / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-08-07T06:42:17Z (GMT). No. of bitstreams: 1
Sartor_JoaoPaulo_M.pdf: 1114989 bytes, checksum: a9fb0b877c769f86e9c6ed9edfffee27 (MD5)
Previous issue date: 2006 / Resumo: O rolipram é um fármaco que possui ação inibidora sobre uma enzima relacionada a processos inflamatórios e tem demonstrado atividade antidepressiva. Ele é comercializado na forma racêmica, isto é, na proporção 1:1 dos seus enantiômeros R e S. No entanto, testes clínicos indicam que o enantiômero R apresenta maior potencial biológico que o enantiômero S. Sendo assim, a separação dos enantiômeros é importante para testes biológicos comparativos de efeitos colaterais. Inserindo-se neste contexto, foi desenvolvido este trabalho de pesquisa com o intuito de estudar a separação deste fármaco pela técnica de cromatografia líquida utilizando coluna empacotada com fase estacionária quiral. Foram determinados os parâmetros analíticos de separação e os dados de equilíbrio e transferência de massa em diferentes condições experimentais. Os resultados mostraram alta eficiência, com número de pratos superando 9000 e fatores de separação na ordem de 1,40. Valores de km superiores a 220 min-1 revelaram baixo efeito dos fenômenos de transferência de massa e conseqüente predomínio dos efeitos termodinâmicos, em destaque à energia entálpica (próxima a -10 kJ/mol para os enantiômeros). Para concentração da mistura até 3,00 mg/mL as isotermas mostraram equilíbrio de adsorção com comportamento linear. Oito colunas cromatográficas foram posteriormente caracterizadas e, a partir dos seus parâmetros analíticos, determinaram-se regiões de separação dos enantiômeros para um sistema cromatográfico contínuo do tipo Leito Móvel Simulado, atendendo diferentes critérios de pureza. Com isso, avaliaram-se as variáveis de desempenho na região de mais alta pureza e o melhor resultado foi simulado a partir de um modelo transiente. Isso possibilitou a determinação do perfil transiente de eluição das correntes de saída e do perfil interno da unidade. As purezas alcançadas para as correntes de extrato e refinado foram 99,99% e 96,74%, respectivamente / Abstract: Rolipram is an enzyme inhibiting anti-inflammatory drug which has also demonstrated antidepressant activity. It is marketed in the racemic form, that is, proportion 1:1 of their R and S-enantiomers. However, clinical tests indicate that the R-enantiomer presents a greater biological potential than S-enantiomer. For this reason their separation is important for comparative biological tests of collateral effects. It is in this context that this research was developed in order to studying the separation of this drug via liquid chromatography using columns packed with chiral stationary phase. Analytical separation parameters, equilibrium and mass transfer data were determined in different experimental conditions. The results revealed high efficiency, with number of plates overcoming 9000 and selectivities in the order of 1.40 for both enantiomers. km values higher than 220 min-1 demonstrated low effect of mass transfer rates and consequently a prevalence of thermodynamic effects; in particular enthalpy energy (next to -10 kJ/mol for both enantiomers). For mixture concentration up to 3.00 mg/mL the isotherms showed adsorption equilibrium with lineal behavior. Next eight chromatographic columns were characterized. Starting with their analytic parameters, the separation regions of the enantiomers were determined for a chromatographic continuous system like Simulated Moving-Bed, with respect to different purity criteria. With that, the performance parameters were evaluated in the highest region of purity and the best result was simulated using a transient model. This permitted the determination of the transient profile of elution in the exit lines and the internal profile of the unit. The purities reached for the extract and raffinate lines were 99.99% and 96.74%, respectively / Mestrado / Desenvolvimento de Processos Biotecnologicos / Mestre em Engenharia Química

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/266191
Date31 July 2006
CreatorsSartor, João Paulo
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Santana, Cesar Costapinto, 1948-, Cremasco, Marco Aurelio, Bonato, Pierina Sueli
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Química, Programa de Pós-Graduação em Engenharia Química
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format134p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0026 seconds