Determinação de dados de equilibrio liquido-vapor e modelagem termodinamica de sistemas contendo alcool alilico

Orientador: Saul Gonçalves D'Avila / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Quimica / Made available in DSpace on 2018-07-21T15:16:32Z (GMT). No. of bitstreams: 1
Castro_LuizAlbertoFalconde_M.pdf: 2806929 bytes, checksum: a6b53ca0a8c5fb3b37ebe54da3bc4c25 (MD5)
Previous issue date: 1996 / Resumo: o equilíbrio líquido-vapor dos binários álcool alílico/acetonitrila, álcool alílico/acetona e álcool alílico/n-hexano foram estudados a partir de dados de equilíbrio determinados na faixa de temperatura de 40 a 80°C. Os dados de equilíbrio líquido-vapor foram obtidos em uma célula de equilíbrio isobárica de circulação do tipo ebuliômetro, disponivel comercialmente, fornecendo dados TPXY. Para o binário álcool alílico/acetonitrila foram levantadas duas curvas experimentais para cobrir a faixa de temperatura de interesse, e para os binários álcool alílico/acetona e álcool alílico/nhexano foram levantadas uma curva para cada um. Foram feitas modificações no ebuliômetro comercial, reduzindo possibilidades de vazamento e melhorando a precisão das medições,a fim de que, o sistema montado, fosse capaz de fornecermedidas de qualidade. Os dados foram comparados com os valores preditos pelo método UNIFAC e suas modificações, sendo os melhores resultados obtidos pela modificação de Dortmund, e foram feitas regressões para encontrar parâmetros do modelo UNIQUAC. O modelo UNIQUAC com seus parâmetros regredidos foi utilizado para a simulação de
uma coluna de separação com os compostos envolvidos mais água, e seus resultados comparados com os dados reais e com a predição pelo modelo UNIFAC e modificações, quando se confirmou a melhor predição obtida pela modificação de Dortmund / Abstract: Vapor-liquid equilibrium measurements for the mixture of allyl alcohol/acetonitrile, allyl alcohol/acetone and allyl alcohol/nhexane at the temperature range between 40 and 80 °C. The experimental data points were obtained on a Ebulliometer,in the TPXY fonn. Two curves were measured for the allyl alcohol/ acetonitrilemixture, in order to cover all the temperature range, and one curve was obtained for each of the allyl alcohol/acetone and allyl alcohol/nhexanemixtures. The Ebuliometer was modified, reducing spill points and improving the measurement precision, so that the data could be obtained with the necessary quality. The VLE data were compared with the prediction made by the UNIFAC method and its modifications, and regressions were made to find UNIQUAC new parameters that fit best the experimental points. The best results were obtained by the Dortmund modification of
the UNIFAC method. The UNIQUAC model with its regressed parameters was used in the simulation of a destilation column with a allyl alcohol, acetonitrile, acetone and water mixture, and the results were comparedwith real plant data and the UNIFAC prediction, that confirmed the best prediction obtainedby the Dortmund modification / Mestrado / Desenvolvimento de Processos Químicos / Mestre em Engenharia Química

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/266731
Date14 June 1996
CreatorsCastro, Luiz Alberto Falcon de
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, D'Avila, Saul Gonçalves, 1942-, Calmonovici, Carlos Eduardo, Maciel, Maria Regina Wolf
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Química, Programa de Pós-Graduação em Engenharia Química
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format93f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess