Return to search

Determinação experimental da curva do sistema e da potência consumida em unidade de bombeamento alimentando dois tanques em desnível com fluidos diferentes / Experimental determination of the curve of the system and power consumed in pumping unit feeding two tanks in different fluids with gap

Orientador: Elias Basile Tambourgi / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Química / Made available in DSpace on 2018-08-19T18:15:28Z (GMT). No. of bitstreams: 1
Pereira_FlavioNelson_M.pdf: 3206674 bytes, checksum: 13d3a08e501d1a7a3efe94db596a1123 (MD5)
Previous issue date: 2011 / Resumo: A bomba centrífuga é uma máquina dinâmica que só pode trabalhar nos pontos de sua curva. Consequentemente, a soma das resistências da tubulação e seus componentes durante a operação deve se situar exatamente na sua curva ou curva da bomba. A literatura para a seleção e especificação deste equipamento alimentando apenas um ponto como um tanque ou vaso é vasta, porém, são raros os trabalhos no que concerne a alimentação simultânea de dois ou mais tanques em cotas diferentes, que mostrem o comportamento da pressão ao longo do processo e a curva desse sistema. Esta alimentação simultânea é dita ramificada. O presente trabalho teve por objetivo projetar e montar uma unidade experimental em escala piloto para determinar a curva do sistema e a potência consumida de uma bomba centrífuga quando esta alimenta dois tanques em cotas diferentes utilizando a água como fluido referência, com viscosidade de 1,0 cP e também uma solução de açúcar a 1,2 cP. A unidade consistiu de um tanque de alimentação de 162,5 L construído em acrílico, uma bomba centrífuga com diâmetro do rotor de 200 mm acoplado a um motor em balanço de 2 CV de potência nominal, um inversor de freqüência para controlar a rotação do motor, tubulações de PVC transparentes de 1 in. de diâmetro nominal na descarga da bomba, um rotâmetro com escala de 0 - 12 m3/h, manômetro com escala 0 - 4 kgf/cm2, e dois tanques em acrílico de 72 L cada na descarga instalados em cotas diferentes. A unidade experimental que operou em regime permanente permitiu a verificação da vazão total e, por conseqüência, a determinação da vazão real em cada trecho ramificado. Os poucos trabalhos teóricos nesta área não comprovam experimentalmente a teoria, não analisam a influência de propriedades físicas e nem estimam a potência do motor. O experimento, portanto, procura comparar os dados coletados com a teoria utilizando fluidos com propriedades físicas diferentes. Este trabalho permitiu comparar os valores teóricos e experimentais com desvio de 12,5 a 20,5%, sendo proposta uma sequência teórica dividida em passos para a determinação do ponto de operação do sistema. O emprego desta sequência proposta permite reduzir os custos de instalação evitando malhas de controle, e os custos operacionais com a redução da energia consumida em sistemas industriais / Abstract: A centrifugal pump is a dynamic machine that can perform only on points on the head capacity curve or curve pump. Consequently, the sum of piping and components resistances during operation must fall exactly on the head capacity curve. The literature for the selection and specification of this equipment feeding only one point as a tank or vessel is large, however is hard to find studies regarding the simultaneous feeding of two or more tanks in different heights and showing the pressure behavior during process and the system curve. This simultaneously feeding is said branched. This study aimed to design and build a pilot-scale experimental unit to determine the system curve and the power consumption of a centrifugal pump when it feeds two tanks in different heights using in fluid viscosity of 1.0 cP, water as fluid reference as well sugar solution to 1.2 cP. The unit consisted of a feed tank of 162.5 L built in acrylic, centrifugal pump with a rotor diameter of 200 mm combined with a balance of motor 2 hp rated power, a frequency inverter to control the engine speed, PVC pipes in a transparent 1 in.nominal discharge of the pump, a flowmeter with a scale from 0 to 12 m3/ h, pressure gauge with a scale from 0 to 4 kgf/cm2, and two tanks of 72 L each in discharge also acrylic installed in different heights. The experimental unit that operated in steady state allowed the verification of the total flow and, consequently, the determination of actual flow in each passage branched. The few theoretical works in this area do not prove the theory experimentally, does not analyze the influence of physical properties and do not estimate the power of the engine. This work allowed us to compare the theoretical and experimental values with deviation of 12,5 to 20,5% being proposed after a theoretical split into steps for determining the operating point of the system. The use of this proposed sequence reduces installation costs by avoiding control loops, and operating costs by reducing the energy consumed in industrial systems / Mestrado / Sistemas de Processos Quimicos e Informatica / Mestre em Engenharia Química

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/266831
Date12 December 2011
CreatorsPereira, Flavio Nelson
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Tambourgi, Elias Basile, 1957-, Junior, Deovaldo de Moraes, Jordão, Elizabete
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia de Campinas, Programa de Pós-Graduação em Engenharia Química
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format73 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0023 seconds