Return to search

Reconhecimento molecular de autoanticorpos e desenvolvimento de sinal colorimentrico utilizando lipossomas polimerizados

Orientadores: Maria Helena Andrade Santana, Ricardo de Lima Zollner / Dissertação (mestrado) - Universidade Estadual de Campinas. Faculdade de Engenharia Quimica / Made available in DSpace on 2018-07-27T04:52:53Z (GMT). No. of bitstreams: 1
Cabral_ElaineChristinedeMagalhaes_M.pdf: 3268697 bytes, checksum: 8b95028e2d3a4b7e0485f9f5f6958725 (MD5)
Previous issue date: 2000 / Resumo: A pesquisa no campo de doenças auto-imunes vem despertando grande interesse, pelas dificuldades de diagnóstico preciso e necessidade de melhor conhecimento das suas causas e mecanismos. O ensaio ELlSA (Enzyme-linked immunosorbent assay) é o mais utilizado para a detecção de auto-anticorpos. Nesse método, os problemas apresentados estão baseados na variabilidade dos kits disponíveis e na natureza multi-etapas envolvida na detecção dos auto-anticorpos. Visando contornar esses problemas, neste trabalho, foi desenvolvido um método de detecção de auto-anticorpos, quantitativo e qualitativo, em única etapa, baseado no reconhecimento molecular e desenvolvimento do sinal colorimétrico, usando lipossomas polimerizados. Na preparação dos lipossomas monoméricos foi usada cardiolipina como ligante específico e ácido 10,12-tricosadiinóico como lipídio estrutural. Os lipossomas polimerizados sob irradiação UV, absorveram a luz no comprimento de onda referente ao azul635nm, púrpura540nm e rosa480nm. A adsorção de auto-anticorpos na superfície dos lipossomas e o desenvolvimento do sinal colorimétrico foram estudados com soros de referência, de indivíduo sadio e auto-imunes. Os resultados experimentais mostraram que a preparação dos lipossomas polimerizados foi reprodutível. A adsorção de auto-anticorpos na superfície. desses lipossomas produziu resposta colori métrica, com alta sensibilidade de mudança de cor do "azul" ou "púrpura" para "rosa", detectável em única etapa. A especificidade do sistema foi 7 vezes maior com soro de referência que com IgG. A utilização de soros auto­imune e sadio reduziu a especificidade do sistema, devido às interferências dos outros componentes do soro. Esses resultados mostraram a potencial idade dos lipossomas polimerizados para a detecção de auto-anticorpos, pela reprodutibilidade do sistema e desenvolvimento de sinal em única etapa / Abstract: The research in the field of autoimmune diseases has been increased in the last years, due to the difficulties on the precise diagnostic, and the knowledgement of its causes and mechanisms. ELlSA (Enzyme -linked immunosorbent assay), commercially available, is the most used method for detection of autoantibodies. The problems presented in its procedure are based on the variability of the commercial kits and on the multi-steps included on the autoantibodies detection. Aiming to circumvent these problems, a alternative method for detection of autoantibodies using polymerized liposomes was developed in this work. The main advantage of this approach is the reprodutibility of the liposomes and the molecular recognition and development of colorimetric signal in only one step. Monomeric liposomes were prepared using cardiolipin a na affinity ligand and 10,12­tricosadiynoic acid as structural lipid. The polymerization was performed by UV irradiation in the blue, purple and pink phase. The adsorption of antibodies and the development of the colorimetric signal was studied using reference, normal and autoimmune sera. The experimental results showed that the polymerized were reprodutibles and stable during 5 months. The adsorption of autoantibodies on the surface of polymerized liposomes produced a colorimetric response trom the blue or purple to pink phase. The sensibility of the system was high, and the specificity was 60% compared the responses with reference serum and non specific immunoglobulin G. When real sera was used, the specificity of decreased due to interferences of the other components of the serum. The results show the potentiality of polymerized liposomes for detection of antibodies, due to reprodutibility of liposomes preparation and development of a colorimetric signal in only one ste / Mestrado / Desenvolvimento de Processos Biotecnologicos / Mestre em Engenharia Química

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/267549
Date09 December 2000
CreatorsCabral, Elaine Christine de Magalhães
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Zollner, Ricardo de Lima, 1954-, Santana, Maria Helena Andrade, 1951-, Cuccovia, Iolanda Midea, Correia, Carlos Roque Duarte
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Engenharia Química, Programa de Pós-Graduação em Engenharia Química
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format118 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0022 seconds