Return to search

Métodos baseados na fotoacústica para caracterização de materiais magnetocalóricos / Methods based on the photoacoustic for characterization of magnetocaloric materials

Orientador: Antonio Manoel Mansanares. / Tese (doutorado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin. / Made available in DSpace on 2018-08-12T12:29:07Z (GMT). No. of bitstreams: 1
Guimaraes_AndreOliveira_D.pdf: 2906238 bytes, checksum: a8ad8b4fc0c3d5bbca6671977306a943 (MD5)
Previous issue date: 2008 / Resumo: Neste trabalho foram desenvolvidas montagens experimentais baseadas na detecção foto acústica para o estudo de materiais magnetocalóricos, que têm despertado um grande interesse na comunidade científica em virtude de suas possíveis aplicações em sistemas de refrigeração. Utilizando o método de dois feixes, para a configuração fotoacústica ar-amostra-ar, foi possível determinar para a difusividade térmica do Gd, em temperatura ambiente, o valor de (4,5 ± 0,2).10-6 m2/s, por meio da amplitude e da fase do sinal fotoacústico normalizado. Medidas da fase do sinal em varreduras de temperatura permitiram a determinação da difusividade térmica em torno da transição magnética (TC), de forma confiáavel e reprodutiva,a com erros menores que 5%. Com base em princípios envolvidos na fotoacústica, foi desenvolvido um método para medidas do efeito magnetocalórico (EMC). O aquecimento gerado nos materiais em questão pela aplicação de um campo magnético alternado (AC), via efeito magnetocalórico, dá origem a ondas de pressão num gás, que são detectadas por um microfone. Discutiu-se sobre os procedimentos de calibracão envolvidos e a metodologia utilizada para a determinação do efeito. Foram realizadas medidas com amostras de Gd e compostos da família Gd5(Ge1-xSix)4, em pó e em pastilhas. Para um campo aplicado de 20 kOe, os valores máximos do EMC vão de 3 K, para o Gd, a 4,5 K, para os compostos ricos em Si, e se referem a transições magnéticas de segunda ordem. Para amostras com x = 0,5, os valores máximos do EMC estão em torno de 1,7 K, referentes a transições magneto-estruturais de primeira ordem. Para alguns destes compostos e possível observar os dois tipos de transição. Os resultados indicam que a técnica se mostra eficiente, não só para as medidas do efeito em si, mas também para a identificação de fases indesejadas, decorrentes do processo de preparação das amostras. Os erros nas medidas do EMC estão em torno de 15 - 20%, comparáveis aos dos métodos convencionais / Abstract: In this work the photoacoustic technique was used to develop experimental setups to investigate magnetocaloric materials, which have been of great interest due to their applications in refrigeration systems. The value (4,5 ± 0,2).10-6 m2/s was determined, at room temperature, as the thermal di usivity of the Gd, based on the two-beam photoacoustic method, by means of both amplitude and phase of the normalized signal. The thermal diffusivity at temperatures around the magnetic transition (TC) was obtained from the photoacoustic signal phase, in temperature scans, in a reproductible and accurate way, with errors below 5%. A method for measuring the magnetocaloric e ect (MCE), based on the acoustic detection, was developed. The temperature oscillations on such materials, due to the application of an alternating magnetic field, produce acoustic waves which can be detected by a microphone. The details concerning the calibration procedure and the proposed methodology to determine the MCE were discussed, and measurements on Gd and Gd 5(Ge1-xSix)4 compouds were performed in powder and pellet samples. For a 20 kOe applied field, the maximum MCE values, related to magnetic second order transitions, are between 3 K, for the Gd, and 4,5 K, for Si - rich compounds. For the samples with x = 0,5, the maximum MCE values are around 1,7 K, related to magneto-structural first order transitions. It is also possible, for some samples, to observe both first and second order transitions. The obtained results point out this acoustic type detection as an effcient technique to measure the magnetocaloric effect, as well as to detect spurious phases present in some of these compounds. The errors in the MCE measurements are about 15-20%, compared to conventional methods / Doutorado / Física da Matéria Condensada / Doutor em Ciências

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/277336
Date12 August 2018
CreatorsGuimarães, André Oliveira
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Mansanares, Antonio Manoel, 1964-, Gandra, Flávio César Guimarães, Sampaio, Juraci Aparecido, Cardoso, Lisandro Pavie, Gama, Sergio
Publisher[s.n.], Universidade Estadual de Campinas. Instituto de Física Gleb Wataghin, Programa de Pós-Graduação em Física
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format74 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0026 seconds