Return to search

Diagnóstico e análise de fuga de partículas pelas extremidades de um constrictor de campo reverso

Orientador: Munemasa Machida / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Fisica Gleb Wataghin / Made available in DSpace on 2018-07-16T00:35:45Z (GMT). No. of bitstreams: 1
Berni_LuizAngelo_M.pdf: 1184013 bytes, checksum: 3119ea616ed26d3352d6877346e71cd5 (MD5)
Previous issue date: 1992 / Resumo: O diagnóstico de fuga de partículas pelas extremidades do TC-1 da UNICAMP foi realizado principalmente, utilizando duas sondas multicanais: magnética e o copo de Faraday.
A sonda magnética interna multicanal (12 canais) foi construída para medir a variação do campo magnético e a influência dos espelhos magnéticos, obtendo um campo de 3,7kG no centro do solenóide e uma razão de espelho de 1,04.
A sonda copo de Faraday multicanal (8 canais) foi usada para estudar a variação espacial e temporal da fuga de partículas pelas extremidades do TC-1. Os ruídos eletromagnéticos e os efeitos de emissão secundária nas medidas foram checados e minimizados usando uma geometria apropriada e instalando a sonda numa cápsula de pirex.
A análise da fuga de partículas mostra que o tempo de vida do plasma é de 30ms ao invés dos 17ms obtidos pela sonda de fluxo excluído. A medida da velocidade de fuga ficou em 1.107cm/s, tendo boa concordância com o valor medido pela sonda de pressão piezoelétrica de 9.106cm/s.
Através do mapeamento tridimensional (r,z,t), nós concluímos que o escape é na forma de anel, o que é comparável com o resultado obtido pela câmara conversora de imagem, e que o plasma não acompanha as linhas de campo na extremidade do solenóide / Abstract: Particle end-loss diagnostics has been performed in the UNICAMP's FRC device TC-1 using mainly two multichannel probes: magnetic and the Faraday cup.
The 12 channel internal magnetic probe has been builted to measure space variations of internal magnetic field and influence of magnetic mirrors obtainning 3.7kG of magnetic strength at the center of the solenoid and 1.04 of field ratio between center and mirror region.
The 8 channel Faraday cup has been used to study space and time variation of particle end-loss from TC-1. The electromagnetic noise and secondary emission effects on the measurements has been checked and minimized using appropriate cup geometry and installed inside a pirex capsule.
The scaping particle analysis show that the useful plasma life time is 30ms instead of 17ms obtained by excluded flux probe measurements. The measured scape particle velocity is 1.107cm/s having good agreement with piezoelectric pressure probe which gives 9.106cm/S.
According to three dimensional mapping (r, z, t) of particle end-loss analysis. we conclude that the scape is in form of a ring in agreement with image converter camera measurements. and the plasma does not follow the field lines at end region / Mestrado / Física / Mestre em Física

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/278425
Date28 October 1992
CreatorsBerni, Luiz Angelo
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Machida, Munemasa, 1950-
Publisher[s.n.], Universidade Estadual de Campinas. Instituto de Física Gleb Wataghin, Programa de Pós-Graduação em Física
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format87f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0025 seconds