Orientadores: Alfonso Schrank, Ronaldo Luiz Mincato, João Frederico Azevedo da Costa Meyer / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Geociencias / Made available in DSpace on 2018-08-04T04:21:32Z (GMT). No. of bitstreams: 1
Amante_AlexandreMarcosdaSilva_M.pdf: 3711986 bytes, checksum: 8ffa9d72a01ef7df56f7ecf1b172ac39 (MD5)
Previous issue date: 2002 / Resumo: Novos resultados isotópicos Pb/Pb do material de referência UQ-Z1 e do padrão de vidro sintético NBS 610, obtidos num Espectrômetro de Massas Multicoletor com Fonte de Plasma de Argônio Indutivamente Acoplado e Introdução da Amostra por Ablação a Laser - LA-ICP-MC-MS, modelo ISO PLASMA TRACE, foram avaliados e tratados sistematicamente. Além do cálculo das idades através das razões Pb/Pb para o UQ-Z1, tais resultados foram comparados com aqueles disponíveis na literatura obtidos por outras técnicas analíticas: ID-TIMS; LA-ICP-MS monocoletor e SHRIMP. O tratamento dos resultados consistiu: na correção do viés de massa do equipamento com base na razão de 2o_IPo3TI do NBS 610; na eliminação das interferências do 204Hg no pico do 2o4Pb a partir das intensidades do 202Hg; na correção do chumbo comum, com base na intensidade do 2o4Pb; e no tratamento estatístico com rejeição de até 15% das razões isotópicas Pb/Pb brutas, considerando a média :± um desvio padrão (1 s). Para o NBS 610, as razões Pb/Pb obtidas neste trabalho são concordantes com aquelas obtidas pelas outras técnicas, apesar da incerteza ser maior. A idade média determinada para o UQ-Z1 foi de 1144 Ma :± 34 (2s). Esse número é próximo ao valor utilizado como referência (1143 Ma ±1 (2s» obtido por ID-TIMS, entretanto com uma incerteza aproximadamente 30 vezes maior. Na comparação com as outras técnicas, as idades obtidas fornecem idades médias mais próximas da idade de referência do que aquelas determinadas por LA-ICP-MS monocoletor (1116 Ma :t 47 (1s) (Machado & Gautier,1996); 1146:t 56 (1s) (Machado et ai., 1996) e 1148:t 5 (2s) (Bruguier et ai., 2001» e por SHRIMP (1138 :t 32 (2s) (Schrank et ai. 1997». Os resultados alcançados demonstram a vantagem relativa da técnica LA-ICP-MC-MS em relação às demais técnicas, tanto na agilidade, como no tempo dispendido, quanto no custo das análises. Na comparação com a técnica ID-TIMS, o LA-ICP-MC-MS apresenta, ainda, a vantagem da análise ser feita diretamente na amostra sólida, sem haver a necessidade de ataques químicos. Os estudos realizados permitem concluir também que o LA-ICP-MC-MS é uma técnica analítica apropriada para estudos sobre a proveniência de sedimentos detríticos, que necessitam de uma grande quantidade de dados de razões isotópicas, de forma a permitir a identificação de zircões com distintas origens / Abstract: New isotopic results Pb/Pb of the UQ-Z1 standard reference and the synthetic glass standard NBS 610, obtained by Laser Ablation Inductively Coupled Plasma Multicollector Mass Spectrometry - LA-ICP-MC-MS, model ISO PLASMA TRACE, have been evaluated and systematically treated. Besides the calculation of the ages through the Pb/Pb ratios for UQ-Z1, such results have been compared with those available in literature by other analytical techniques: ID-TIMS; monocollector LA-ICP-MS and SHRIMP. The results of treatment consisted in: 1) the mass bias correction of the equipment based on the 2o_lpO3TI ratios of NBS 610; 2) the elimination of the 204Hg interferences on the peak of 204Pb from the 202Hg intensities; 3) the common lead correction based on the 204Pb intensities; 4) the statistical treatment with rejection of up to 15% of raw isotopic Pb/Pb ratios, considering the average ± 1 standard deviation (1 s). The Pb/Pb ratios of the NBS 6100btained in this work agree with other techniques, despite the larger uncertainty. The average age determined for the UQ-Z1 was 1144 Ma ± 34 (2s). This number is close to the value used as reference (1143 Ma ± 1 (2s)) obtained by ID-TIMS, however, approximately30 times larger uncertainty. Compared with other techniques, the ages obtained yielded average ages closest to the reference age than the ages determined by monocollector LA-ICP-MS (1116 Ma ± 47 (1s) (Machado & Gautier, 1996); 1146 :t 56 (1s) (Machado et aI., 1996) and 1148 :t 5 (2s) (Bruguier et aI., 2001)) and by SHRIMP (1138 :t 32 (2s) (Schrank et aI. 1997)). The achieved results demonstrate the advantage of the LA-ICP-MC-MS technique in relation to others, as well as in speed, in the time spent and in the lower cost of the analyses. In comparison with the ID-TIMS technique, the LA-ICP-MC-MS presents still another advantage as the measurements are made directly on the solid sample without previous chemical attacks. From these studies it can also be concluded that the LA-ICP-MC-MS is an appropriate analytical technique for studies on the provenience of detritic sediments that need a great amount of data of isotopic ratios, to allow the identification of zircon with distinct origins / Mestrado / Metalogenese / Mestre em Geociências
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/287467 |
Date | 28 June 2002 |
Creators | Amante, Alexandre Marcos da Silva |
Contributors | UNIVERSIDADE ESTADUAL DE CAMPINAS, Schrank, Alfonso, 1951-, Meyer, João Frederico da Costa Azevedo, 1947-, Mincato, Ronaldo Luiz, Enzweiler, Jacinta, Dantas, Elton Luiz |
Publisher | [s.n.], Universidade Estadual de Campinas. Instituto de Geociências |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | Portuguese |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis |
Format | 99f. : il., application/pdf |
Source | reponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0031 seconds