Return to search

Avaliação de técnicas de fixação interna estável da osteotomia sagital dos ramos mandibulares = estudos mecânico, fotoelástico, análise de elementos finitos e de estabilidade clínica / Evaluation of the rigid stable techniques of the sagittal split ramus osteotomies : mechanical, photoelastic, finite elements analysis and clinical stability studies

Orientadores: Márcio de Moraes, Luciana Asprino / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T03:16:09Z (GMT). No. of bitstreams: 1
Sato_FabioRicardoLoureiro_D.pdf: 2302649 bytes, checksum: 79991cfb8902f00e046ae324c6bd0664 (MD5)
Previous issue date: 2011 / Resumo: O objetivo nesse trabalho foi avaliar a resistência mecânica, a distribuição de tensões e a estabilidade em longo prazo das diversas formas de fixação da osteotomia sagital dos ramos mandibulares (OSRM). No trabalho 1, cinco técnicas de fixação da OSRM foram submetidas a análise de elementos finitos: 3 parafusos bicorticais lineares a 60° e a 90°, 3 parafusos bicorticais em disposição L invertido, 1 miniplaca com 4 parafusos monocorticais convencionais e com sistema de travamento. Pelos resultados obtidos, a disposição em L invertido foi a que apresentou melhor distribuição de tensões, seguido pela linear 90° e 60°. Em relação às miniplacas, as tensões apresentaram melhor distribuição naquela com sistema de travamento se comparada com a convencional. No trabalho 2, foi realizada um análise mecânica, fotoelástica e de elementos finitos da chamada técnica híbrida, comparando-a com a fixação tradicional com três parafusos bicorticais em L invertido e com miniplaca e parafusos monocorticais. A técnica híbrida apresentou resistência intermediária entre os dois sistemas tradicionais de fixação da OSRM, com concentração de tensões principalmente ao redor do parafuso bicortical e melhora da distribuição de tensões na região da miniplaca. No trabalho 3, foi realizada uma análise da estabilidade esquelética de três formas de fixação da OSRM: técnica híbrida, parafusos bicorticais e miniplacas/parafusos monocorticais. Os resultados mostraram não haver diferença estatisticamente significante entre os três grupos, sendo positiva a correlação entre a quantidade de avanço mandibular e a quantidade de recidiva. Pelos resultados obtidos nos trabalhos, pode-se concluir que todas as técnicas avaliadas podem ser empregadas com segurança na fixação da osteomia sagital dos ramos mandibulares / Abstract: The aim of this research was to evaluate the mechanical resistance, stress distribution and long-term stability of fixation techniques of the sagittal split ramus osteotomy (SSRO). In the first study, five fixation techniques of the SSRO were submitted to finite element analysis: 3 linear screws 90°, 3 linear screws 60°, 3 screws in inverted L arrangement, conventional and locking miniplate with monocortical screws. The results demonstrated that the bicortical screws in inverted L arrangement presented the best stress distribution, followed by linear 90° and linear 60°. The locking system miniplate presented better stress distribution if compared with conventional miniplate and monocortical screws. In the second study, a mechanical, photoelastic and finite element analysis were performed to the so-called hybrid technique, comparing it with bicortical screws in inverted L arrangement and miniplate with monocortical screws. The hybrid technique had an intermediate mechanical resistance between the two traditional fixation techniques, with high stress concentration around the bicortical screw with improvement in the stress distribution around the miniplate. In the third study, skeletal stability was evaluated of three fixation techniques of the SSRO: the hybrid technique, bicortical screws and miniplates with monocortical screws. The results demonstrated no significant statistically difference between the groups, with a positive correlation between the amount of advancement and relapse. From the results obtained in the research, it is possible to conclude that all fixation techniques could be safely applied to sagital split ramus osteotomy / Doutorado / Cirurgia e Traumatologia Buco-Maxilo-Faciais / Doutor em Clínica Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/287898
Date18 August 2018
CreatorsSato, Fábio Ricardo Loureiro
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Asprino, Luciana, 1974-, Moraes, Marcio de, 1966-, Elias, Fernando Melhem, Almeida, Priscila Domingues de, Noritomi, Pedro Yoshito, Caria, Paulo Henrique Ferreira
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format117 p. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0025 seconds