Return to search

Estudo eletromiografico dos musculos iliocostal lombar, semitendineo e biceps da coxa (cabeça longa) no vita-house

Orientador: Fausto Berzin / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-20T09:18:20Z (GMT). No. of bitstreams: 1
Masselli_MariaRita_D.pdf: 11375087 bytes, checksum: 89469c294326314620762e24637d1eab (MD5)
Previous issue date: 1995 / Resumo: A eletromiografia (EMG) dos músculos iliocostal lombar, semitendíneo e bíceps da coxa foi registrada durante exercício de fortalecimento dos músculos flexores da perna realizado no aparelho denominado Vita-house. O banco deste aparelho é dotado de dobradiças, de maneira que pode ser utilizado nas formas de mesa plana ou de mesa inclinada. Na forma inclinada, a angulação de 138° na mesa proporciona ao indivíduo aplanamento da lordose lombar e uma flexão de 42° na articulação do quadril colocando, desta maneira, todos os músculos analisados em posição de alongamento. Foram examinados, com pares de eletrodos de superfície, 22 voluntários de ambos os sexos, não sedentários. Os voluntários realizavam contrações isométricas aos 30° e 60° de flexão dos joelhos, com carga de 5kg e 10kg. Foi utilizado um eletrogoniômetro para garantir a precisão dos ângulos pré-determinados. Análises de variância e testes de Tukey complementares foram usados para comparar os registros nas duas formas de mesa, nos dois ângulos, nos dois músculos flexores da perna e nos sexos masculino e feminino. De acordo com os resultados, a variável sexo não determinou diferença no sinal eletromiográfico. Na comparação de músculos, a EMG foi menor no músculo bíceps da coxa do que no músculo semitendíneo. Verificou-se que a EMG registrada aos 60° de flexão dos joelhos foi maior provavelmente porque a força de resistência neste ângulo é maior do que aos 30°. Quanto à forma da mesa, verificou-se que a EMG registrada na mesa plana foi maior do que na mesa inclinada para os três músculos examinados. De acordo com os resultados, os músculos isquiotibiais deveriam ser testados e exercitados com o quadril flexionado para tirar vantagem da relação comprimento-tensão muscular e também para prevenir o aparecimento de dor lombar / Abstract: The purpose of this study was to examine the influence of the subject position on Vita-house (equipment offitness) ofthe iliocostalis lumborum and hamstring signal EMG. The equipment called Vita-Jwuse has a hinge on the board, upon which the subject could either lie prone (plain table), or over which the subject could be draped, as the board hinged at its center (tilt table). The tilt table provides 42 degrees of hip flexion and flattening lumbar lordosis, which place ali these muscles in stretching. Twenty two healty volunteers of both sexes, no sedentary, were studied electromyographicalIy using surface electrode. The volunteers performed two isometric contractions at angles of 30 and 60 degrees of knee flexion against resistances of 5 and 10 kg. The angles were controled by using a electrogoniol1).eter. Analysis of variance and complementary Tukey's test were used to study the repeated measures design involving the four factors (table, muscle, angel and sex). The results demonstrate that the sex factor do not determinded different signal EMG. The electrical signal colIected from semitendinous muscle were significantly higher than biceps femoris muscle. The signal EMG colIected at angle of 60 degrees of knee flexion were higher than at angle of 30 degrees, maybe because the resistance force at 60 degrees is higher than at angle of 30 degrees. Comparison of the table, involving the comparison ofthe two forms (plain and tilt) demonstrate, as expected, that the signal EMG at the plain table exceed significantly the signal at the tilt table, for the thre examined muscles. The results suggest that the hamstring should be tested and exercised with the hip flexed (in tilt table) to allow for maximal torque development, and to take advantage of the length-tension relationship of the muscle and to prevent appearance of the low back pain / Doutorado / Biologia e Patologia Buco-Dental / Doutor em Ciências

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/288801
Date20 July 2018
CreatorsMasselli, Maria Rita
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Bérzin, Fausto, 1940-
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Ciências
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format90f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0186 seconds