Return to search

Comparação entre imagens obtidas de telerradiografia lateral convencional, e imagens de tomografia computadorizada de feixe conico, na região da sinfise mentoniana / Comparing lateral teleradiography (LT) images with sagital section of cone-beam compued tomography (CBCT) in the mandibular shymphisys area

Orientador: Frab Norberto Boscolo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-15T03:02:59Z (GMT). No. of bitstreams: 1
Rodrigues_Messias_M.pdf: 1187476 bytes, checksum: 1b1617668cea9154e821cbb731522fd3 (MD5)
Previous issue date: 2010 / Resumo: O objetivo com este estudo foi comparar imagens de Telerradiografia Lateral (TL) e de corte sagital mediano em Tomografia Computadorizada de Feixe Cônico (TCFC) pela exatidão da marcação de pontos na região de Sínfise Mandibular. A amostra com 28 TL e 28 TCFC, foi obtida de 28 pacientes submetidos a tratamento ortodôntico, os quais tinham características anatômicas semelhantes, na região de Sínfise Mandibular. Dez (10) examinadores calibrados analisaram todas as imagens, separadamente, em 2 períodos distintos, marcando seis pontos na região da Sínfise Mandibular, sendo eles: 1 - Ápice, 2 - Borda Incisal, 3 - Infradentário Lingual, 4 - Infradentário Vestibular, 5 - Mentoniano Interno, 6 - Mentoniano Externo. A definição dos pontos de referência, padrão prata, foi realizada por outro avaliador sem blindagem com as imagens, de TL e de TCFC, postas lado a lado. A distância, entre os pontos de referência e os marcados pelos avaliadores, foi mensurada com uma grade milimetrada superposta às imagens. Foi utilizado o coeficiente de correlação interclasses (CCI) para avaliar a reprodutibilidade intra- e inter-examinadores, e as distâncias entre os pontos marcados foram analisados pelo teste de Wilcoxon (a=0,05). Nos resultados observou-se que os pontos, Borda Incisal, Mentoniano Interno e Externo não apresentaram diferenças estatisticamente significativas (p>0,05) de distâncias entre as marcações, por outro lado os pontos Infradentário Vestibular e Lingual apresentaram diferenças (p<0,05). Baseado nos resultados obtidos pode-se concluir que a região da parte inferior da Sínfise Mandibular e Borda Incisal são locais que, para fins de diagnóstico, podem ser visualizados na TL com a mesma exatidão que a imagem tomográfica. Por outro lado, quando o local requisitado para diagnóstico estiver situado na altura mediana das raízes dos incisivos, tanto pela face vestibular quanto pela lingual, somente a imagem de TCFC oferece condições de visualização com exatidão das estruturas ali situadas. / Abstract: The aim with this study was to compare images of Lateral Teleradiography (LT) and sagittal section of Cone-Beam Computed Tomography (CBCT) through the exactness of landmarks made in the Mandibular Shymphisys region. The sample with 28 LT and 28 CBCT was obtained from 28 patients undergoing orthodontic treatment, which had similar anatomical features in the Mandibular Shymphisys region. 10 calibrated examiners evaluated all images, separately, in 2 distinct periods, marking six points in the Mandibular Shymphisys area, which are: 1 - Root Apex, 2 - Incisal Edge, 3 - Lingual Infradentale, 4 - Buccal Infradentale, 5 - Internal Mentum, 6 - External Mentum. Another examiner without blindness made the definition of factual landmarks, LT and CBCT, placed side by side. The distance between points (factual landmarks and those marked by the examiners) was measured with a millimeter grid superimposed to images. The interclass correlation coefficient (ICC) was used to evaluate the reliability intra- and inter-examiners, and the distance between marked points was analyzed using the Wilcoxon test (a=0.05). The results showed that statistical differences were not found in distances between Incisal Edge, in Internal Mentum and External Mentum points (p>0.05), on the other hand, Buccal Infradentale and Lingual Infradentale points were differences (p<0.05). In accordance with results, it can be concluded that the lower area of the Symphysis Mandibular and the Incisal Edge point are regions that to diagnosis finality can be visualized in the LT with the same exactness that in the CBCT. Therefore, when the region to diagnosis was the Symphysis Mandibular in middle region of incisor root, as much Buccal as Lingual faces, only the CBCT image supplied conditions to precise visualization of their anatomic structures. / Mestrado / Radiologia Odontologica / Mestre em Radiologia Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/288879
Date15 August 2018
CreatorsRodrigues, Messias
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Boscolo, Frab Norberto, 1942-, Cruz, Adriana Dibo da, Almeida, Solange Maria de
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Radiologia Odontológica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format36 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0025 seconds