Return to search

Validade e reprodutibilidade de medidas cefalométricas derivadas da reconstrução de imagens em 2D e 3D de tomografias computadorizadas de feixe cônico / Validity and reproducibility of cephalometric measurements obtained from 2D and 3D cone beam computed tomography images reconstructed

Orientador: Frab Norberto Bóscolo / Dissertação (Mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba. / Made available in DSpace on 2018-08-17T21:27:03Z (GMT). No. of bitstreams: 1
Ramirez-Sotelo_LauraRicardina_M.pdf: 5567474 bytes, checksum: 98cd4142814ba81a64a557cf5eecb5ea (MD5)
Previous issue date: 2011 / Resumo: A telerradiografia em norma lateral é utilizada como a ferramenta essencial e padrão da avaliação da morfologia maxilofacial. O objetivo neste trabalho foi testar a validade e a reprodutibilidade das medidas das grandezas cefalométricas angulares nas imagens 2D e 3D derivadas da reconstrução de tomografia computadorizada de feixe cônico, comparando-as com as medidas obtidas na telerradiografia convencional em norma lateral. Avaliaram-se as imagens telerradiograficas convencionais e tomográficas de 58 indivíduos. Dois examinadores, independentemente e em momentos distintos, avaliaram as telerradiografias convencionais e a média das medidas foi considerada como "padrão ouro". Outros três examinadores realizaram a avaliação das reconstruções 2D e 3D da tomografia, em dois momentos diferentes. Observou-se que todas as modalidades apresentaram diferenças significativas nas medidas das grandezas angulares exceto: na modalidade de telerradiografia virtual RaySum em 2D, para os ângulos SNB, altura facial inferior, eixo facial e cone facial; na modalidade de telerradiografia virtual em 2D de máxima intensidade, para as grandezas SNA, SNB, eixo facial, inclinação IS e cone facial; e, na modalidade de telerradiografia por cortes tomográficos em 3D, para os ângulos eixo facial, IMPA e inclinação IS em ambos os lados e para as grandezas SNA e SNB apenas no lado esquerdo. Porém, mesmo com as diferenças estatisticamente significativas encontradas, apenas o ângulo FMIA, interincisivo, inclinação IS e IMPA apresentaram diferenças absolutas entre as médias das medidas, acima dos 2° e 3°. A correlação entre as modalidades 2D e 3D, bem como entre essas com as telerradiografias convencionais foram excelentes. Concluiu-se que as medidas angulares nas imagens 2D e 3D reconstruídas da tomografia computadorizada de feixe cônico são reproduzíveis e válidas, comparando-as com as medidas obtidas na telerradiografia em norma lateral, e que mesmo que algumas tenham apresentado diferenças estatísticas significativas, elas não representam valores clínicos relevantes na avaliação cefalométrica como um todo / Abstract: The lateral cephalometric radiography is used as the standard and essential tool for assessing maxillofacial morphology. The main of this study was to test the validity and reproducibility of angular cephalometric measurements of images derived from 2D and 3D reconstruction of cone beam computed tomography, and compared them with measurements obtained in conventional lateral cephalometric radiography. Was evaluated the tomographys and conventional cephalometric images of 58 patients. Two operators, independently at different times, evaluated the conventional cephalometric radiographs and means of measurements was considered the "gold standard". Other three operators performed the evaluation of 2D and 3D reconstructions of volumetric tomography in two different times. It was observed that all modalities has significant differences in the angular measures except: in the modality of virtual radiography RaySum 2D for the SNB angle, lower facial height, facial axis and facial taper; in the modality of virtual radiography 2D maximum intensity, for the measurements SNA, SNB, facial axis, IS inclination and facial taper; in the form of radiography for 3D tomographic images for the facial axis, IMPA and IS inclination, on both sides, the angles SNA and SNB only for the left side. However, even with statistically significant differences found, only the angle FMIA, interincisal, IS inclination and IMPA showed absolute differences between the averages of above 2 ° and 3 °. The correlation between 2D and 3D, and between those with conventional radiographs were excellent. It was concluded that the angular measurements in 2D and 3D images reconstructed from cone beam computed tomography are reproducible and valid, comparing them with measurements obtained from lateral cephalometric radiography, and even though some have shown statistically significant differences, they do not represent values in the relevant clinical cephalometric evaluation as a whole / Mestrado / Radiologia Odontologica / Mestre em Radiologia Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/288922
Date17 August 2018
CreatorsRamírez-Sotelo, Laura Ricardina, 1982-
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Boscolo, Frab Norberto, 1942-, Freitas, Deborah Queiroz de, Almeida, Solange Maria de
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Radiologia Odontológica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format80 p, : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0025 seconds