Return to search

Analise comparativa, in vitro, da eficiencia na odontometria de tres localizadores apicais (Root ZX, Bingo 1020 e Novapex).

Orientador: Francisco Jose de Souza Filho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-04T10:07:50Z (GMT). No. of bitstreams: 1
Santos_JulioCesarBentodos_D.pdf: 777651 bytes, checksum: ead9155fe00aa49ebe36b753c9c89d8a (MD5)
Previous issue date: 2005 / Resumo: A presente pesquisa teve por finalidade avaliar, in vitro, a eficácia dos localizadores apicais, Bingo 1020, Novapex e Root ZX, nas posições 1mm aquém do ápice e na posição 0 (zero). Comparar a odontometria eletrônica na posição 0 com a medida real dos dentes. Comparar a odontometria radiográfica com a odontometria eletrônica utilizando o Bingo 1020 na posição 1mm aquém do ápice e na posição 0. Para tanto foram utilizadas 71 raízes de molares humanos, extraídos, com rizogênese completa e sem sinais de fratura apical. Dos molares inferiores utilizou-se raízes mesiais e dos molares superiores as raízes vestibulares. Foi realizada a abertura coronária . Após a radiografia, sendo essa o segundo critério de seleção, os dentes foram colocados em uma plataforma para a odontometria eletrônica. Essa plataforma teve a finalidade de manter os dentes em posição, com os respectivos ápices em contato com uma solução salina . A exploração do canal foi realizada com as limas 10 e 15 e a odontometria com a lima 20, sendo que a medida real foi obtida com lupa de aumento de 2,5 vezes , considerando a posição em que a lima emergia da constrição apical. A primeira medida eletrônica foi realizada na posição em que o localizador apical marcou 1mm aquém do ápice. A segunda medida, na posição 0. Esse procedimento foi realizado com os três localizadores apicais, perfazendo um total de 213 medidas na posição 1mm e 213 medidas na posição 0. Quarenta e quatro canais foram utilizados para avaliação radiográfica. O cálculo estatístico demonstrou que os localizadores apicais Bingo 1020, Novapex e Root ZX não foram significativamente diferentes entre si, nas medidas 1mm aquém do ápice e na posição 0mm, nas condições da pesquisa. Na comparação com a medida real o Root ZX apresentou uma maior porcentagem de aproximação, embora não significante, nos desvios de 0,5 mm e 0,75mm. Na odontometria radiográfica, considerando três avaliadores, houve diferença estatisticamente signicante em dois, em relação à odontometria eletrônica com o localizador apical Bingo 1020 / Abstract: The aim of this study was to evaluate, in vitro, the measurement efficiency of the apex locators known as Bingo 1020, Novapex and Root ZX, at the positions of 1mm and 0mm from the apex; compare the electronic measurement at 0mm with the real measurement of the teeth; and compare the radiographic root canal measurement to the electronic measurement obtained by the Bingo 1020. For this, 71 extracted human molar roots, presenting complete root formation and no signs of apical fracture were selected and only the mesial roots of the inferior molars and the buccal roots of the superior molars were included in the study. The teeth were embedded in a resin ring and coronary access and radiographs were performed. After tooth radiography, considered the second criteria for selection, these were placed upon a platform for electronic root measurement. Such platform had the finality to maintain the teeth in position, with the respective apexes in contact with saline solution. Canal exploration was accomplished using files #10 and 15#, root measurement was performed with a file #20, and the real root measurement was determined when file emergence from the apical constriction was observed using a 2.5X magnifying glass. The first electronic measurement was made when the apex locator marked 1mm from the apex. The second measurement was noted at 0mm. Such sequence was performed using the three apex locators, adding up to a total of 213 measurements at 1mm and at 0mm from the apex. Forty-four root canals were used for radiographic evaluation. Statistic evaluation demonstrated that the apex locators Bingo 1020, Novapex and Root ZX were not statistically different among each other at the measurements of 1mm and 0mm from the apex under the conditions of this experiment. During the comparison with real root measurements, Root ZX presented the highest percentage approximation, although not statistically significant during deviation of 0.5mm and 0.75mm. Three different evaluators revealed significant statistical difference among two, when radiographic root measurement were compared to the Bingo 1020 apex locator / Doutorado / Endodontia / Doutor em Clínica Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/289060
Date28 February 2005
CreatorsSantos, Julio Cesar Bento dos
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Souza Filho, Francisco José de, 1950-2014, Simões, Waldocyr, Luiz, Marcone Reis, Valdrighi, Luiz, Gomes, Brenda Paula Figueiredo de Almeida
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format82f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0032 seconds