Return to search

Analise da deformação de componentes de protese fixa implantossuportada quando submetidos a cargas axiais e obliquas por meio de extensometria / Analysis of the deformation of the components of implant-suported prosthesis when submitted to axial and obliques loads by mean of the extensometry

Orientador: Wilkens Aurelio Buarque e Silva / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T03:30:15Z (GMT). No. of bitstreams: 1
Costa_MarcelodeAlmeida_D.pdf: 2169259 bytes, checksum: 40e31d0384a05e3f5b7c97d6657b6364 (MD5)
Previous issue date: 2009 / Resumo: Este trabalho teve como objetivo, avaliar através da extesometria, a resposta de forças aplicadas sobre abutments de infra-estrutruras implanto-retidas fundidas em ligas de cobalto-cromo, pela técnica de monobloco, simulando caso de protocolo mandibular, foram utilizados 06 implantes com distância de 10 mm entre implantes e com extremo livre Cantilever bilateral com tamanho do 20 mm. Em cada abutment foram colados 04 extensometros, fazendo uma ponte de Wheatstone, após apertamento de todos os componentes a peça em monobloco, foi submetido a um ensaio mecânico com cargas compressivas com valores de 150 N/cm, analisando quantitativamente os dados através da extensômetria, permitindo resultados bem precisos. Os referidos resultados foram obtidos usando os maiores valores registrados em cada ponto de força aplicado, ou seja, nos lados: esquerdo e direito ( cantilever bilateralmente), tanto para carga axial ou em 20º, demonstrou pura deflexão, porem quando a aplicação foi entre as fixações( implantes ) P1eP2,P3eP4,P4 eP5, P5eP6, respectivamente, foi obtido nas fixações mais próximas a aplicação da carga um maior grau de compressão (deflexão) e nas fixações mais distantes uma pequena deflexão negativa indo até conseguir uma deflexão positiva, sugerindo movimento de gangorra / Abstract: The objective of this study was evaluate through extensometry the response of implant-suported frameworks in cobalt-chromium submitted to a load by the technique of monoblock, that simulate a case of mandibular protocol with 06 implants with a distance of 10 mm between each implant and a bilateral cantlever of 20 mm. In each abutment were pasted 04 strain gauges, making a bridge of Wheatstone, after squeezing all components of the piece of the monoblock, was submitted to a test with mechanical compressive loads with values of 150 N, quantitatively analyzing the data through extensometry, allowing accurate results. The results were obtained using the highest values recorded at each point of force applied, in the points L and R (cantilever bilaterally) for both axial load or 20, showed pure deflection, but when the load was applyed between p1 and p2, P3eP4, P4 eP5, P5eP6 respectively, was obtained a greater degree of compression (deflection) closer to the application of the load and more dstant to the applicarion of load, a little negative deflection was found by going to a positive deflection, suggesting movement of seesaw / Doutorado / Protese Dental / Doutor em Clínica Odontológica

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/290248
Date02 November 2009
CreatorsCosta, Marcelo de Almeida
ContributorsUNIVERSIDADE ESTADUAL DE CAMPINAS, Silva, Wilkens Aurelio Buarque e, 1967-, Paixão, Fernanda, Zanatta, Giuliana, Landulpho, Alexandre Brait, Moreira, Roger William Fernandes
Publisher[s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Clínica Odontológica
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguageEnglish
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis
Format81 f. : il., application/pdf
Sourcereponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0015 seconds