Orientadores: Antonio Carlos Pereira, Mario A. Coelho Sinhoreti / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T18:50:53Z (GMT). No. of bitstreams: 1
Pardi_Vanessa_D.pdf: 2278132 bytes, checksum: 707d334aa58b758590632e60e1480f0b (MD5)
Previous issue date: 2004 / Resumo: Selantes de fissuras têm sido considerados eficazes na prevenção de cárie oclusal, entretanto há controvérsias na literatura quanto ao material de escolha para o procedimento de selamento. Desse modo, o presente trabalho composto por 4 artigos tem como objetivos: I) descrever o desempenho dos selantes de fóssulas e fissuras ao longo dos anos e discutir sua importância como método preventivo; 2) avaliar clinicamente 3 diferentes materiais aplicados como seiantes de fissuras (Vitremer, Dyract Flow e Revolution) após 2 anos de aplicação clínica; 3) comparar, in vitro, o desgaste e mudanças na rugosidade superficial de 4 materiais odontológicos (Delton, Filtek Flow, Dyract Flow e Vitremer) aplicados como selantes após abrasão por escovação e dentifrício; 4) avaliar, in vitro, a infiltração marginal em seiantes de fissuras realizados com diferentes materiais odontológicos (Delton, Filtek Flow, Dyract Flow e Vitremer). Em relação à revisão sobre selantes, foi concluído que eles são eficazes na prevenção de cárie e suas indicações e contra-indicações devem ser cuidadosamente avaliadas pelos profissionais. Os resultados após dois anos de aplicação clínica permitiram concluir que a resina composta de alto escoamento Revolution apresentou a melhor taxa de retenção, embora não tenha havido diferença estatisticamente significante em relação à presença de cárie entre os grupos. Quanto à resistência à abrasão, não houve diferença estatisticamente significante entre os materiais Vitremer e Dyract Flow e nem entre Filtek Flow e Delton, entretanto os primeiros apresentaram maior taxa de desgaste. O material Vitremer apresentou o maior valor de rugosidade, enquanto o material Delton apresentou o menor valor após o teste de abrasão. Em relação ao teste de microinfiltração, embora todos os materiais estudados tenham apresentado um certo grau de microinfiltração, não houve diferença estatisticamente significante entre os mesmos. O contínuo estudo de materiais odontológicos para a aplicação como selantes de fissuras é recomendado, uma vez que avanços tecnológicos podem contribuir para a melhora das propriedades físicas dos materiais e, conseqüentemente, para a melhora de seu comportamento clínico / Abstract: Fissure sealants had been considered efficacious on occlusal caries prevention, however there are controversies in the literature with regard to the material to apply. This present study, composed by four articles, has the following aims: a) to describe the performance of the fissure sealants and to discuss their relevance as a preventive method; b) to evaluate three different materiaIs (Vitremer, Dyract Flow and Revolution) used as an occlusal sealant after 2-year clinical application; c) to compare the in vitro wear and changes on the superficial roughness of different materiaIs (Delton, Filtek Flow, Dyract Flow e Vitremer) used as fissure sealant after abrasion with toothbrush and dentifrice and d) to evaluate the in vitro microleakage of different materiaIs used as fissure sealants (Delton, Filtek Flow, Dyract Flow e Vitremer). Regarding the review (a), it was concluded that the fissure sealant is efficacious on caries prevention and the indications and contraindications of this proceeding should be carefully evaluated by professionals. In the 2-year clinical evaluation (b) was verified that Revolution showed the best retention rate, however there was no statistically significant difference with regard to caries presence after the evaluated period among the groups (Revolution, Dyract Flow and Vitremer). With reference to the abrasion test (c), there were no statistically significant difference either between Vitremer and Dyract Flow or Filtek Flow and Delton, however the former showed the highest wear before the abrasion test. Vitremer showed the highest roughness measurement, while Delton showed the lowest measurement after the abrasion test. Regarding the microleakage test (d), although all the materiaIs had exhibited some degree of microleakage, there were no statistically significant difference among them. A continuous study of dental materiaIs to apply as fissure sealants is recommended, since that technological advances can contribute to the improvement of physical properties of dental materiaIs and consequent1yto the improvement of their clinical behavior / Doutorado / Cariologia / Doutor em Odontologia
Identifer | oai:union.ndltd.org:IBICT/oai:repositorio.unicamp.br:REPOSIP/290351 |
Date | 29 January 2004 |
Creators | Pardi, Vanessa |
Contributors | UNIVERSIDADE ESTADUAL DE CAMPINAS, Sinhoreti, Mário Alexandre Coelho, 1969-, Pereira, Antonio Carlos, 1967-, Hofling, Roberta Tarkany Basting, Silva, Silvio Rocha Correa da, Correr Sobrinho, Lourenço, Meneghim, Marcelo de Castro |
Publisher | [s.n.], Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba, Programa de Pós-Graduação em Odontologia |
Source Sets | IBICT Brazilian ETDs |
Language | Portuguese |
Detected Language | English |
Type | info:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/doctoralThesis |
Format | 86f. : il., application/pdf |
Source | reponame:Repositório Institucional da Unicamp, instname:Universidade Estadual de Campinas, instacron:UNICAMP |
Rights | info:eu-repo/semantics/openAccess |
Page generated in 0.0026 seconds