Return to search

Biocompatibilidade do cimento endodôntico AH plus acrescido de hidróxido de cálcio em subcutâneo de rato / Biocompaatibility of AH plus endodontic sealer increased of calcium hydroxide in subcutaneous of rats

Made available in DSpace on 2015-12-06T23:44:38Z (GMT). No. of bitstreams: 0
Previous issue date: 2006 / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Introdução: No tratamento dos canais radiculares, todas as fases devem ser
consideradas atos operatórios independentes. Atenção maior tem sido dada a
uma resposta biológica pós - tratamento. Embora, o AH Plus apresente boa
resposta biológica em relação aos tecidos apicais e periapicais, os cimentos à
base de hidróxido de cálcio são, ainda, a primeira escolha nos casos em que
tolerância, reparação e ação antimicrobiana nesses tecidos são desejadas.
Portanto, levando em consideração as excelentes propriedades físico-químicas
do AH Plus, achou-se oportuno a realização de estudo biológico para
confirmar se o acréscimo de hidróxido de cálcio proporcionaria melhora da
biocompatibilidade do produto. Objetivo: Determinar a biocompatibilidade
do cimento endodôntico AH Plus acrescido de hidróxido de cálcio a 5% em
peso. Métodos: Foram utilizados 30 ratos distribuídos em 3 grupos de 10
animais. Tubos de silicone contendo os materiais em teste foram implantados,
um por animal, no subcutâneo do dorso: Grupo I – animais implantados com
tubos contendo AH Plus puro; Grupo II – contendo AH Plus acrescido de
hidróxido de cálcio e Grupo III – tubos vazios (controle). A
biocompatibilidade foi determinada pela análise quali e quantitativa da reação
inflamatória. Resultados: O tecido adjacente ao tubo evidenciou processo
inflamatório crônico inespecífico, qualitativamente semelhante nos três grupos
experimentais. Quantitativamente, os animais implantados com o cimento
acrescido de hidróxido de cálcio 5% em peso apresentaram reação
inflamatória menos intensa que o grupo implantado com o cimento puro.
Conclusão: O acréscimo de 5% em peso de hidróxido de cálcio ao cimento
endodôntico AH Plus promove melhor biocompatibilidade do que o AH Plus
puro em tecido subcutâneo de rato. / Introduction: In the treatment of root canals, every phases must be
considered independent operatives. A greater attention has been given to a
biological response pos-treatment. Although, the AH Plus presents good
biological response in relation to the apicals and peripicals tissues, the sealers
containing calcium hydroxide are still the first choice in cases in which
tolerance, reparation and anti-microbian actions in such tissues are desirable.
Thus, considering the excellent physiochemical properties of the AH Plus, it
was considered opportune the realization of a biological study to confirm if
the increase of calcium hydroxide would supply improvement of the product
biocompatibility. Aims: To determine the biocompatibility to AH Plus
endodontic sealer, additioned of calcium hydroxide to 5% in weight.
Methods: 30 rats, distributed in 3 groups of 10 animals, were used. Silicon
tubes containing materials in test were implanted, to each animal, in the
subcutaneous of the back dorsum. Group I – animals implanted with tubes
containing pure AH Plus; Group II containing AH Plus added with calcium
hydroxide and Group III – empty tubes (control). The biocompatibility was
determined by the qualitative and quantitative analysis of inflammatory
reaction. Results: The adjacent tissue to the tube attested a not specific
chronic inflammatory process, qualitatively similar in the three experimental
groups. Quantitatively, the animals implanted with cement added with calcium
hydroxide 5% in weight presented inflammatory reaction less intense than the
group implanted with pure cement. Conclusion: The increase of 5% in weight
calcium hydroxide to the AH Plus sealer promotes better biocompatibility than
pure AH Plus in the subcutaneous tissues of rats. / BV UNIFESP: Teses e dissertações

Identiferoai:union.ndltd.org:IBICT/oai:repositorio.unifesp.br:11600/21446
Date January 2006
CreatorsOliveira, Ricardo Leão de [UNIFESP]
ContributorsUniversidade Federal de São Paulo (UNIFESP), Oliveira Filho, Renato Santos de [UNIFESP]
PublisherUniversidade Federal de São Paulo (UNIFESP)
Source SetsIBICT Brazilian ETDs
LanguagePortuguese
Detected LanguagePortuguese
Typeinfo:eu-repo/semantics/publishedVersion, info:eu-repo/semantics/masterThesis
Format85 f.
Sourcereponame:Repositório Institucional da UNIFESP, instname:Universidade Federal de São Paulo, instacron:UNIFESP
Rightsinfo:eu-repo/semantics/openAccess

Page generated in 0.0024 seconds